ASTM D 7237 : 2015
NA
Status of Standard is Unknown
Standard Test Method for Free Cyanide and Aquatic Free Cyanide with Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection
Hardcopy , PDF
English
01-02-2015
Committee |
D 19
|
DocumentType |
Test Method
|
Pages |
10
|
PublisherName |
American Society for Testing and Materials
|
Status |
NA
|
SupersededBy | |
Supersedes |
1.1This test method is used to establish the concentration of free cyanide in an aqueous wastewater, effluent and in-stream free cyanide concentrations after mixing treated water with receiving water. The test conditions of this test method are used to measure free cyanide (HCN and CN-) and cyanide bound in the metal-cyanide complexes that are easily dissociated into free cyanide ions at the pH of 6. Free cyanide is determined at pH 6 at room temperature. The aquatic free cyanide can be determined by matching the pH to the water in the receiving environment in the range of pH 6 to 8. The extent of HCN formation is less dependent on temperature than the pH; however, the temperature can be regulated if deemed necessary for aquatic free cyanide to further simulate the actual aquatic environment.
1.2The free cyanide test method is based on the same instrumentation and technology that is described in Test Method D6888, but employs milder conditions (pH 6-8 buffer versus HCl or H2SO4 in the reagent stream), and does not utilize ligand displacement reagents.
1.3The aquatic free cyanide measured by this procedure should be similar to actual levels of HCN in the original aquatic environment. This in turn may give a reliable index of toxicity to aquatic organisms.
1.4This procedure is applicable over a range of approximately 5to 500 μg/L (parts per billion) free cyanide. Sample dilution may increase cyanide recoveries depending on the cyanide speciation; therefore, it is not recommended to dilute samples. Higher concentrations can be analyzed by increasing the range of calibration standards or with a lower injection volume. In accordance with Guide E1763E1763 and Practice D6512 the lower scope limit was determined to be 9 μg/L for chlorinated gold leaching barren effluent water and the IQE10 % is 12 µg/L in the gold processing detoxified reverse osmosis permeate waste water sample matrix.
1.5The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in 8.6 and Section 9.
ASTM D 7365 : 2009 : REV A : R2015 | Standard Practice for Sampling, Preservation and Mitigating Interferences in Water Samples for Analysis of Cyanide |
ASTM E 2242 : 2013 | Standard Test Method for Column Percolation Extraction of Mine Rock by the Meteoric Water Mobility Procedure |
ASTM E 1600 : 2015 | Standard Test Methods for Determination of Gold in Cyanide Solutions |
ASTM D 7572 : 2015 | Standard Guide for Recovery of Aqueous Cyanides by Extraction from Mine Rock and Soil |
ASTM D 4193 : 2008 : R2013 : EDT 1 | Standard Test Method for Thiocyanate in Water |
ASTM D 6696 : 2016 | Standard Guide for Understanding Cyanide Species |
ASTM D 7728 : 2018 | Standard Guide for Selection of ASTM Analytical Methods for Implementation of International Cyanide Management Code Guidance |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.