ASTM D 7339 : 2018 : REDLINE
Current
The latest, up-to-date edition.
Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography
English
01-03-2018
CONTAINED IN VOL. 11.07, 2018 Defines an analytical procedure for identifying and quantifying the masses of individual volatile organic compounds (individual VOCs or IVOCs) that are emitted into a flow of air from carpet specimens and collected on sorbent sampling tubes during emissions testing.
Committee |
D 22
|
DocumentType |
Redline
|
Pages |
12
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
1.1This test method describes an analytical procedure for identifying and quantifying the masses of individual volatile organic compounds (individual VOCs or IVOCs) that are emitted into a flow of air from carpet specimens and collected on sorbent sampling tubes during emissions testing.
1.2This test method will be used in conjunction with a standard practice for sampling and preparing carpet specimens for emissions testing. If a specific chamber practice is not available for the carpet specimens, this test method should be used in conjunction with approved standard practices for emissions testing and sample preparation.
1.3When used in conjunction with standard practices for carpet specimen preparation and collection of vapor-phase emissions , this test method will provide a standardized means of determining the levels of IVOC in the exhaust stream of the emissions test chamber/cell. If this test method is used with a reliable practice for emissions testing, these IVOC levels can be used to determine the emission rate from a unit quantity (usually surface area) of the sample material under test.
1.4VOCs in the exhaust stream of an emissions test device are collected on thermal desorption tubes packed with a specific combination of sorbents using active (pumped) sampling. (See Practice D6196 for a more general description of vapor collection using pumped sampling onto sorbent tubes.) The samples are analyzed by thermal desorption (TD) with gas chromatography and mass spectrometry detection (GC/MS) and/or flame ionization detection (FID) depending upon the requirements of the specific materials emissions testing/certification protocol.
1.5This test method can be used for the measurement of most GC-compatible organic vapors ranging from the approximate volatility from n-hexane to n-hexadecane (that is, compounds with vapor pressures ranging from 16 kPa to 4 × 10-4 kPa at 25°C). Properties other than a compound’s vapor pressure such as affinity for the sorbent may need to be taken into account. Compounds with vapor pressures outside this range may or may not be quantifiable by this test method. However, qualitative data concerning the identity of a compound(s), outside the stated volatility range for quantitation, may still be useful to the user. This test method can be applied to analytes over a wide concentration range—typically 1 μg/m3 to 1 mg/m3 concentration of vapor in the exhaust air from the emission cell or chamber.
1.6This test method is not capable of quantifying all compounds which are emitted from carpets. See the appropriate test practices/methods for determining other compounds that are not amenable to analysis by gas chromatography (that is, Test Method D5197 for the determination of aldehydes).
1.7Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.9This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D 7706 : 2017 : REDLINE | Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers |
ISO 10580:2010 | Resilient, textile and laminate floor coverings Test method for volatile organic compound (VOC) emissions |
ASTM D 3686 : 2013 : REDLINE | Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method) |
ISO 16000-9:2006 | Indoor air — Part 9: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test chamber method |
ASTM D 5197 : 2016 : REDLINE | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 7143 : 2017 : REDLINE | Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products |
ISO 16000-10:2006 | Indoor air — Part 10: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test cell method |
ISO 16000-11:2006 | Indoor air — Part 11: Determination of the emission of volatile organic compounds from building products and furnishing — Sampling, storage of samples and preparation of test specimens |
ISO 16000-6:2011 | Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.