• There are no items in your cart

ASTM D 7474 : 2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Determining Residual Stresses in Extruded or Molded Sulfone Plastic (SP) Parts by Immersion in Various Chemical Reagents

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Superseded by

ASTM D 7474 : 2017

Language(s)

English

Published date

01-04-2012

€59.22
Excluding VAT

Committee
D 20
DocumentType
Standard Practice
Pages
4
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This practice covers the evaluation of residual stresses in extruded profile or molded SP parts. The presence and relative magnitude of residual stresses are indicated by the crazing of the specimen part upon immersion in one or more of a series of chemical reagents. The specified chemical reagents were previously calibrated by use of Environmental Stress Cracking (ESC) techniques to cause crazing in sulfone plastics (SP) at specified stress levels.

1.2 This practice applies only to unfilled injection molding and extrusion grade materials of high molecular weight as indicated by the following melt flow rates: PSU 9 g/10 min, max., PESU 30 g/10 m, max, and PPSU 25 g/10 min, max. Lower molecular weight (higher melt flow) materials will craze at lower stress levels than indicated in Tables 1-3. (See Specification D6394 for melt flow rate conditions.)

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

Note 1—There is no known ISO equivalent for this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

TABLE 1 Liquid Reagents for Residual Stress Test for PSU

MixtureMixture CompositionCritical Stress, MPa (psi)
% by volume Ethanol% by volume Ethyl Acetate
1505015.2 (2200)
2435712.1 (1750)
337639.0 (1300)
425755.5 (800)

TABLE 2 Liquid Reagents for Residual Stress Test for PESU

MixtureMixture CompositionCritical Stress, MPa (psi)
% by volume Ethanol% by volume MEK
1505017.9 (2600)
2406010.3 (1500)
320806.9 (1000)
401005.9 (850)

TABLE 3 Liquid Reagents for Residual Stress Test for PPSU

MixtureMixture CompositionCritical Stress, MPa (psi)
% by volume Ethanol% by volume MEK
1505022.8 (3300)
2257513.8 (2000)
310909.0 (1300)
401008.0 (1150)

ASTM F 702 : 2018 Standard Specification for Polysulfone Resin for Medical Applications

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.