ASTM D 7600 : 2009 : EDT 2

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Determination of Aldicarb, Carbofuran, Oxamyl and Methomyl by Liquid Chromatography/Tandem Mass Spectrometry

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

01-12-2009

€67.30
Excluding VAT

Committee
D 19
DocumentType
Test Method
Pages
10
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This procedure covers the determination of aldicarb, carbofuran, oxamyl and methomyl (referred to collectively as carbamates in this test method) in surface water by direct injection using liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS). These analytes are qualitatively and quantitatively determined by this method. This method adheres to multiple reaction monitoring (MRM) mass spectrometry.

1.2This test method has been developed by US EPA Region 5 Chicago Regional Laboratory (CRL).

1.3The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4The Detection Verification Level (DVL) and Reporting Range for the carbamates are listed in Table 1.

TABLE 1 Detection Verification Level and Reporting Range

Analyte

DVL (ng/L)†

Reporting Range (μg/L)

Aldicarb

100

1–100

Carbofuran

100

1–100

Oxamyl

100

1–100

Methomyl

100

1–100

† Measurement editorially corrected.


1.4.1The DVL is required to be at a concentration at least 3 times below the Reporting Limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 displays the signal/noise ratios of the primary single reaction monitoring (SRM) transitions and Fig. 2 displays the confirmatory SRM transitions at the DVLs for the carbamates.

Example Primary SRM Chromatograms Signal/Noise Ratios
FIG. 1Example Primary SRM Chromatograms Signal/Noise Ratios
Example Confirmatory SRM Chromatograms Signal/Noise Ratios
FIG. 2Example Confirmatory SRM Chromatograms Signal/Noise Ratios

1.4.2The reporting limit is the concentration of the Level 1 calibration standard as shown in Table 2 for the carbamates.

TABLE 2 Concentrations of Calibration Standards (PPB)

Analyte/Surrogate

LV 1

LV 2

LV 3

LV 4

LV 5

LV 6

Aldicarb

1

5

10

25

50

100

Carbofuran

1

5

10

25

50

100

Oxamyl

1

5

10

25

50

100

Methomyl

1

5

10

25

50

100

BDMC (Surrogate)

2

10

20

50

100

200


1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.