Standard Test Method for Determination of Aldicarb, Aldicarb Sulfone, Aldicarb Sulfoxide, Carbofuran, Methomyl, Oxamyl, and Thiofanox in Water by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)
Hardcopy , PDF
25-05-2023
English
08-06-2016
This procedure covers the determination of aldicarb, aldicarb sulfone, aldicarb sulfoxide, carbofuran, methomyl, oxamyl, and thiofanox (referred to collectively as carbamates in this test method) in water by direct injection using liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS).
Committee |
D 19
|
DocumentType |
Test Method
|
Pages |
14
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This procedure covers the determination of aldicarb, aldicarb sulfone, aldicarb sulfoxide, carbofuran, methomyl, oxamyl, and thiofanox (referred to collectively as carbamates in this test method) in water by direct injection using liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS). These analytes are qualitatively and quantitatively determined by this test method. This test method adheres to multiple reaction monitoring (MRM) mass spectrometry.
1.2The Detection Verification Level (DVL) and Reporting Range for the carbamates are listed in Table 1.
1.2.1The DVL is required to be at a concentration at least 3 times below the Reporting Limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 displays the signal/noise ratios of the primary single reaction monitoring (SRM) transitions, and Fig. 2 displays the confirmatory SRM transitions at the DVLs for the carbamates.
1.2.2The reporting limit is the concentration of the Level 1 calibration standard as shown in Table 2 for the carbamates.
1.3Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 3694 : 1996 : R2011 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 4841 : 1988 : R2008 | Standard Practice for Estimation of Holding Time for Water Samples Containing Organic and Inorganic Constituents |
ASTM D 1129 : 2003 | Standard Terminology Relating to Water |
ASTM D 4841 : 1988 : R2018 | Standard Practice for Estimation of Holding Time for Water Samples Containing Organic and Inorganic Constituents |
ASTM D 1129 : 2013 | Standard Terminology Relating to Water |
ASTM D 1129 : 2013 : R2020 | Standard Terminology Relating to Water |
ASTM D 5847 : 1999 : REV A : EDT 1 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 3694 : 1996 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 2777 : 2012 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 1193 : 1977 : R1983 : EDT 1 | Standard Specification for Reagent Water |
ASTM D 4841 : 1988 : R1998 | Standard Practice for Estimation of Holding Time for Water Samples Containing Organic and Inorganic Constituents |
ASTM D 5847 : 2002 : R2007 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 1129 : 2006 | Standard Terminology Relating to Water |
ASTM D 2777 : 2003 | Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water |
ASTM D 2777 : 2021 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 4841 : 1988 : R2003 | Standard Practice for Estimation of Holding Time for Water Samples Containing Organic and Inorganic Constituents |
ASTM D 2777 : 2013 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM E 2554 : 2013 | Standard Practice for Estimating and Monitoring the Uncertainty of Test Results of a Test Method Using Control Chart Techniques |
ASTM D 4841 : 1988 : R2013 | Standard Practice for Estimation of Holding Time for Water Samples Containing Organic and Inorganic Constituents |
ASTM D 5847 : 2002 : R2012 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 2777 : 1998 | Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water |
ASTM D 3694 : 1996 : R2017 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 1129 : 2013 : R2020 : EDT 1 | Standard Terminology Relating to Water |
ASTM D 1129 : 1999 : REV A | Standard Terminology Relating to Water |
ASTM D 3856 : 2011 | Standard Guide for Management Systems in Laboratories Engaged in Analysis of Water |
ASTM D 1129 : 2006 : REV A | Standard Terminology Relating to Water |
ASTM D 1193 : 2006 : R2011 | Standard Specification for Reagent Water |
ASTM D 5847 : 2002 : R2020 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 1129 : 2003 : REV A | Standard Terminology Relating to Water |
ASTM D 3694 : 1996 : R2004 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 1129 : 2002 | Standard Terminology Relating to Water |
ASTM E 2554 : 2018 : EDT 1 | Standard Practice for Estimating and Monitoring the Uncertainty of Test Results of a Test Method Using Control Chart Techniques |
ASTM D 1193 : 1991 | Standard Specification for Reagent Water |
ASTM D 3856 : 1995 : R2006 | Standard Guide for Good Laboratory Practices in Laboratories Engaged in Sampling and Analysis of Water |
ASTM D 1129 : 2004 | Standard Terminology Relating to Water |
ASTM D 5847 : 2022 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 2777 : 2008 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM E 2554 : 2007 | Standard Practice for Estimating and Monitoring the Uncertainty of Test Results of a Test Method in a Single Laboratory Using a Control Sample Program |
ASTM D 3856 : 2011 : R2015 | Standard Guide for Management Systems in Laboratories Engaged in Analysis of Water (Withdrawn 2024) |
ASTM D 2777 : 2006 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 3856 : 1995 : R2000 | Standard Guide for Good Laboratory Practices in Laboratories Engaged in Sampling and Analysis of Water |
ASTM D 1129 : 2002 : REV A | Standard Terminology Relating to Water |
ASTM E 2554 : 2018 | Standard Practice for Estimating and Monitoring the Uncertainty of Test Results of a Test Method Using Control Chart Techniques |
ASTM D 5847 : 2002 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 1193 : 1970 | Standard Specification For Reagent Water |
ASTM D 4841 : 1988 : R2013 : EDT 1 | Standard Practice for Estimation of Holding Time for Water Samples Containing Organic and Inorganic Constituents |
ASTM D 1193 : 2006 | Standard Specification for Reagent Water |
ASTM D 1193 : 1999 | Standard Specification for Reagent Water |
ASTM D 1129 : 2010 | Standard Terminology Relating to Water |
ASTM D 1129 : 2006 : REV A : EDT 1 | Standard Terminology Relating to Water |
ASTM D 1129 : 2001 | Standard Terminology Relating to Water |
ASTM D 1129 : 2004 : EDT 1 | Standard Terminology Relating to Water |
ASTM D 1193 : 2006 : R2018 | Standard Specification for Reagent Water |
ASTM D 2777 : 2008 : EDT 1 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.