ASTM D 7668 : 2017 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Determination of Derived Cetane Number (DCN) of Diesel Fuel Oils—Ignition Delay and Combustion Delay Using a Constant Volume Combustion Chamber Method
08-12-2023
English
01-11-2017
CONTAINED IN VOL. 05.05, 2017 Specifies the quantitative determination of the derived cetane number of conventional diesel fuel oils, diesel fuel oils containing cetane number improver additives, and is applicable to products typical of Specification D975, Grades No.1-D and 2-D regular, low and ultra-low-sulfur diesel fuel oils, European standard EN590, and Canadian standards CAN/CGSB-3.517 and CAN/CGSB 3.6.
Committee |
D 02
|
DocumentType |
Redline
|
Pages |
13
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This test method covers the quantitative determination of the derived cetane number of conventional diesel fuel oils, diesel fuel oils containing cetane number improver additives, and is applicable to products typical of Specification D975, Grades No.1-D and 2-D regular, low and ultra-low-sulfur diesel fuel oils, European standard EN590, and Canadian standards CAN/CGSB-3.517 and CAN/CGSB3.6. The test method may be applied to the quantitative determination of the derived cetane number of biodiesel, blends of diesel fuel oils containing biodiesel material (for example, Specifications D975, D6751, and D7467), and diesel fuel oil blending components.
1.2This test method utilizes a constant volume combustion chamber with direct fuel injection into heated, compressed synthetic air. A dynamic pressure wave is produced from the combustion of the sample. An equation converts the ignition delay and the combustion delay determined from the dynamic pressure curve to a derived cetane number (DCN).
1.3This test method covers the ignition delay ranging from 1.9 ms to 25 ms and combustion delay ranging from 2.5 ms to 160 ms (30 DCN to 70 DCN). However, the precision stated only covers the range of DCN from 39 to 67.
1.4The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
14/30295249 DC : 0 | BS EN 16715 - LIQUID PETROLEUM PRODUCTS - DETERMINATION OF IGNITION DELAY AND DERIVED CETANE NUMBER (DCN) OF MIDDLE DISTILLATE FUELS - IGNITION DELAY AND COMBUSTION DELAY DETERMINATION USING A CONSTANT VOLUME COMBUSTION CHAMBER WITH DIRECT FUEL INJECTION |
BS EN 16715:2015 | Liquid petroleum products. Determination of ignition delay and derived cetane number (DCN) of middle distillate fuels. Ignition delay and combustion delay determination using a constant volume combustion chamber with direct fuel injection |
PD CEN/TR 17103:2017 | Petroleum and related products. Fast pyrolysis bio-oils for stationary internal combustion engines. Quality determination |
I.S. EN 16715:2015 | LIQUID PETROLEUM PRODUCTS - DETERMINATION OF IGNITION DELAY AND DERIVED CETANE NUMBER (DCN) OF MIDDLE DISTILLATE FUELS - IGNITION DELAY AND COMBUSTION DELAY DETERMINATION USING A CONSTANT VOLUME COMBUSTION CHAMBER WITH DIRECT FUEL INJECTION |
S.R. CEN/TR 17103:2017 | FAST PYROLYSIS BIO-OILS FOR STATIONARY INTERNAL COMBUSTION ENGINES - QUALITY DETERMINATION |
IP 615 : 2016 | LIQUID PETROLEUM PRODUCTS - DETERMINATION OF IGNITION DELAY AND DERIVED CETANE NUMBER (DCN) OF MIDDLE DISTILLATE FUELS - IGNITION DELAY AND COMBUSTION DELAY DETERMINATION USING A CONSTANT VOLUME COMBUSTION CHAMBER WITH DIRECT FUEL INJECTION |
SAE J 313 : 2017 | DIESEL FUELS |
ASTM D 1655 : 2018-01 | SPECIFICATION FOR AVIATION TURBINE FUELS |
EN 16715:2015 | Liquid petroleum products - Determination of ignition delay and derived cetane number (DCN) of middle distillate fuels - Ignition delay and combustion delay determination using a constant volume combustion chamber with direct fuel injection |
UNE-EN 16715:2016 | Liquid petroleum products - Determination of ignition delay and derived cetane number (DCN) of middle distillate fuels - Ignition delay and combustion delay determination using a constant volume combustion chamber with direct fuel injection |
DIN EN 16715:2015-10 | Liquid petroleum products - Determination of ignition delay and derived cetane number (DCN) of middle distillate fuels - Ignition delay and combustion delay determination using a constant volume combustion chamber with direct fuel injection |
ASTM D 7467 : 2017-03 | SPECIFICATION FOR DIESEL FUEL OIL, BIODIESEL BLEND (B6 TO B20) |
CEN/TR 17103:2017 | Petroleum and related products - Fast pyrolysis bio-oils for stationary internal combustion engines - Quality determination |
CGSB 3.6 : 2010 | OFF-ROAD DIESEL FUEL |
ASTM D 7467 : 2017-03 | SPECIFICATION FOR DIESEL FUEL OIL, BIODIESEL BLEND (B6 TO B20) |
IP 41 : 2015 | PETROLEUM PRODUCTS - DETERMINATION OF THE IGNITION QUALITY OF DIESEL FUELS - CETANE ENGINE METHOD |
CGSB 3.517 : 2017 | DIESEL FUEL |
DIN 73372:1978-08 | FUEL INJECTION NOZZLES, SIZE T AND U |
Access your standards online with a subscription