ASTM D 7706 : 2017 : REDLINE
Current
The latest, up-to-date edition.
Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers
English
12-06-2017
CONTAINED IN VOL. 11.07, 2017 Defines a micro-scale chamber apparatus and associated procedures for rapidly screening materials and products for their vapor-phase emissions of volatile organic compounds (VOCs) including formaldehyde and other carbonyl compounds.
Committee |
D 22
|
DocumentType |
Redline
|
Pages |
10
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
1.1This practice describes a micro-scale chamber apparatus and associated procedures for rapidly screening materials and products for their vapor-phase emissions of volatile organic compounds (VOCs) including formaldehyde and other carbonyl compounds. It is intended to complement, not replace reference methods for measuring chemical emissions for example, small-scale chamber tests (Guide D5116) and emission cell tests (Practice D7143).
1.2This practice is suitable for use in and outside of laboratories, in manufacturing sites and in field locations with access to electrical power.
1.3Compatible material/product types that may be tested in the micro-scale chamber apparatus include rigid materials, dried or cured paints and coatings, compressible products, and small, irregularly-shaped components such as polymer beads.
1.4This practice describes tests to correlate emission results obtained from the micro-scale chamber with results obtained from VOC emission reference methods (for example, Guide D5116, Test Method D6007, Practice D7143, and ISO 16000-9 and ISO 16000-10).
1.5The micro-scale chamber apparatus operates at moderately elevated temperatures, 30°C to 60°C, to eliminate the need for cooling, to reduce test times, boost emission rates, and enhance analytical signals for routine emission screening, and to facilitate screening of semi-volatile VOC (SVOC) emissions such as emissions of some phthalate esters and other plasticizers.
1.6Gas sample collection and chemical analysis are dependent upon the nature of the VOCs targeted and are beyond the scope of this practice. However, the procedures described in Test Method D7339, Practice D6196 and ISO 16000-6 for analysis of VOCs and in Test Method D5197 and ISO 16000-3 for analysis of formaldehyde and other carbonyl compounds are applicable to this practice.
1.7The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.9This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D 7859 : 2013 | Standard Practice for Spraying, Sampling, Packaging, and Test Specimen Preparation of Spray Polyurethane Foam (SPF) Insulation for Testing of Emissions Using Environmental Chambers |
17/30362165 DC : 0 | BS EN 16402 - PAINTS AND VARNISHES - ASSESSMENT OF EMISSIONS OF SUBSTANCES FROM COATINGS INTO INDOOR AIR - SAMPLING, CONDITIONING AND TESTING |
BS EN 16516:2017 | Construction products: Assessment of release of dangerous substances. Determination of emissions into indoor air |
I.S. EN 16516:2017 | CONSTRUCTION PRODUCTS: ASSESSMENT OF RELEASE OF DANGEROUS SUBSTANCES - DETERMINATION OF EMISSIONS INTO INDOOR AIR |
ASTM D 7911 : 2014 | Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test |
EN 16516:2017 | Construction products: Assessment of release of dangerous substances - Determination of emissions into indoor air |
ASTM D 7859 : 2013 : EDT 1 | Standard Practice for Spraying, Sampling, Packaging, and Test Specimen Preparation of Spray Polyurethane Foam (SPF) Insulation for Testing of Emissions Using Environmental Chambers |
ASTM D 7339 : 2018 : REDLINE | Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography |
ASTM D 5116 : 2017 : REDLINE | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products |
SAE J 2989 : APR 2018 | HANDLING AND PACKAGING OF MATERIALS AND COMPONENTS FOR EMISSIONS TESTING |
ASTM D 8142 : 2017 | Standard Test Method for Determining Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation using Micro-Scale Environmental Test Chambers |
ASTM D 8141 : 2017 | Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Parameters for Modeling of Indoor Environments |
ISO 16000-9:2006 | Indoor air — Part 9: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test chamber method |
ASTM D 5197 : 2016 : REDLINE | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ISO 16000-3:2011 | Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method |
ASTM D 7143 : 2017 : REDLINE | Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM D 7339 : 2012 | Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography |
ISO 16000-10:2006 | Indoor air — Part 10: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test cell method |
ASTM D 6007 : 2014 : REDLINE | Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber |
ISO 16000-6:2011 | Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.