• Shopping Cart
    There are no items in your cart

ASTM D 7730 : 2011

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Determination of Dioctyl Sulfosuccinate in Sea Water by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)

Available format(s)

Hardcopy , PDF

Superseded date

20-05-2024

Superseded by

ASTM D 7730 : 2017

Language(s)

English

Published date

01-05-2011

€74.48
Excluding VAT

Committee
D 19
DocumentType
Test Method
Pages
11
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 This procedure covers the determination of dioctyl sulfosuccinate (DOSS) in sea water by direct injection using liquid chromatography (LC) and detection with tandem mass spectrometry (MS/MS). This analyte is qualitatively and quantitatively determined by this method. This method adheres to selected reaction monitoring (SRM) mass spectrometry.

1.2 The Detection Verification Level (DVL) and Reporting Range for DOSS are listed in Table 1.

1.2.1 The DVL is required to be at a concentration at least 3 times below the Reporting Limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 and Fig. 2 display the signal/noise ratio of the selected reaction monitoring (SRM) transition.

1.2.2 The reporting limit is the concentration of the Level 1 calibration standard as shown in Table 5 for DOSS, taking into account the 50% sample preparation dilution factor.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

TABLE 1 Detection Verification Level and Reporting Range

AnalyteDVL (μg/L)Reporting Range (μg/L)
DOSS320-400


FIG. 1 Detection Verification Level Signal/Noise Ratio.


FIG. 2 Reporting Level Signal/Noise Ratio.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.