ASTM D 7845 : 2013

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Determination of Chemical Species in Marine Fuel Oil by Multidimensional Gas Chromatography – Mass Spectrometry

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Superseded by

ASTM D 7845 : 2016

Language(s)

English

Published date

01-04-2013

€74.48
Excluding VAT

Committee
D 02
DocumentType
Test Method
Pages
11
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This test method covers the quantitative determination of a variety of chemical species in marine fuel oil (bunker fuel oil) by gas chromatography – mass spectrometry. By using the same conditions and by selecting required mass spectral selected ions, the test method may be used for the determination of other species than those for which precision statements and limits of detection have been established.

1.2An example list of chemical species for which a limit of quantification has been determined by means of this test method is given in Table 1.

TABLE 1 Component Table

Limit of Quantitation
mg/kg

n-butyl alcohol

10

Cyclohexanol

10

n-butyl ether

10

n-butyl acylate

10

Styrene

10

alpha-pinene

10

Phenol

20

alpha-methyl styrene

10

beta-pinene

10

4-methyl styrene

10

trans-B-methyl styrene

10

3-methyl styrene

10

2-methyl styrene

10

Dicyclopentadiene

10

Limonene

10

Indene

20

1-phenyl ethanol

20

para, alpha-Dimethyl styrene

20

2,5 dimethyl styrene

20

2,4 dimethyl styrene

20

2-phenyl ethanol (phenylethanol)

20

2-Ethyl Phenol

50

2,4 Dimethyl Phenol

20

4-Ethyl Phenol (co elutes with 3-ethylphenol)

20

2-Phenoxy-1-propanol

50

2-Phenoxy ethanol

50

4-isopropylphenol

50

1-Phenoxy-2-Propanol

20

Styrene Glycol

50


1.3Other refinery hydrocarbon fractions and their mixtures may be tested using the same test method conditions. However, the precision of this test method reflects the compounds in Table 1.

1.4Results are reported to the nearest 1.0 mg/kg.

1.5The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.