• Shopping Cart
    There are no items in your cart

ASTM D 7979 : 2017 : REDLINE

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Determination of Per- and Polyfluoroalkyl Substances in Water, Sludge, Influent, Effluent and Wastewater by Liquid Chromatography Tandem Mass Spectrometry (LC/MS/MS)

Available format(s)

PDF

Superseded date

20-04-2020

Language(s)

English

Published date

15-07-2017

€96.91
Excluding VAT

CONTAINED IN VOL. 11.02, 2017 Defines the determination of selected perfluorinated compounds (PFCs) in a water matrix using liquid chromatography (LC) and detection with tandem mass spectrometry (MS/MS).

Committee
D 19
DocumentType
Redline
Pages
32
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This procedure covers the determination of selected per- and polyfluoroalkyl substances (PFASs) in a water matrix using liquid chromatography (LC) and detection with tandem mass spectrometry (MS/MS). These analytes are qualitatively and quantitatively determined by this method. This method adheres to a technique known as selected reaction monitoring (SRM) or sometimes referred to as multiple reaction monitoring (MRM). This is not a drinking water method, performance of this test method has not been evaluated on drinking water matrices.

1.2The Method Detection Limit (MDL)2 and Reporting Range3 for the target analytes are listed in Table 1. The target concentration for the reporting limit for this test method was 10 ng/L for most of the target analytes at the time of development.

TABLE 1 Method Detection Limit and Reporting Range

AnalyteA

MDL
(ng/L)

Reporting Ranges
(ng/L)

PFTreAB

1.2

10 – 400

PFTriAB

0.7

10 – 400

PFDoAB

1.2

10 – 400

PFUnAB

1.2

10 – 400

PFDAB

1.4

10 – 400

PFOSB

2.2

10 – 400

PFNAB

1.1

10 – 400

PFecHSB

1.9

10 – 400

PFOAB

1.7

10 – 400

PFHxSB

1.2

10 – 400

PFHpAB

1.0

10 – 400

PFHxAB

2.0

10 – 400

PFBSB

0.8

10 – 400

PFPeAB

4.6

50 – 2000

PFBAB

4.6

50 – 2000

FHEA

92.9

300 – 8000

FOEA

106.8

300 – 8000

FDEA

47.2

200 – 8000

FOUEA

2.3

10 – 400

FHpPA

3.3

10 – 400

FHUEA

1.5

10 – 400

(A)Acronyms are defined in 3.3.
(B)New MDL study was reported in August 2016, which resulted in a reporting limit and range update.

1.2.1The reporting limit in this test method is the minimum value below which data are documented as non-detects. The reporting limit may be lowered providing your lab meets the minimum performance requirements of this test method at the lower concentrations, this method is performance based and modifications are allowed to improve performance. Analyte detections between the method detection limit and the reporting limit are estimated concentrations and are not reported following this test method. In most cases, the reporting limit is the concentration of the Level 1 calibration standard as shown in Table 4 for the PFASs after taking into account the 50 % dilution with methanol. It is above the Level 1 calibration concentration for FHEA and FOEA, these compounds can be identified at the Level 1 concentration but the standard deviation among replicates at this lower spike level resulted in a higher reporting limit.

1.3The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM D 1129 : 2013 : REDLINE Standard Terminology Relating to Water
ASTM D 2777 : 2013 : REDLINE Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
ASTM E 2554 : 2013-05 PRACTICE FOR ESTIMATING AND MONITORING THE UNCERTAINTY OF TEST RESULTS OF A TEST METHOD USING CONTROL CHART TECHNIQUES
CFR 40(PTS136-149) : JUL 2017 PROTECTION OF ENVIRONMENT - ENVIRONMENTAL PROTECTION AGENCY