ASTM D 8084 : 2017
Current
The latest, up-to-date edition.
Standard Test Method for Photoelectrochemical Oxygen Demand of Freshwater Sources for Drinking Water Treatment Plants and Treated Drinking Water
Hardcopy , PDF
English
15-07-2017
CONTAINED IN VOL. 11.02, 2017 Defines a protocol for the determination of the photoelectrochemical oxygen demand of freshwater sources for drinking water treatment plants and treated drinking water in the range of 0.7 mg/L to 20 mg/L.
Committee |
D 19
|
DocumentType |
Test Method
|
Pages |
9
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
Supersedes |
1.1This test method covers a protocol for the determination of the photoelectrochemical oxygen demand of freshwater sources for drinking water treatment plants and treated drinking water in the range of 0.7 mg/L to 20 mg/L. Higher levels may be determined by sample dilution.
1.2Photoelectrochemical oxygen demand is determined using the current generated from the photoelectrochemical oxidation of the sample using titanium dioxide (TiO2) irradiated with ultraviolet (UV) light from a light-emitting diode (LED).
1.3This test method does not require the use of the hazardous reagents, such as mercuric sulfate, potassium dichromate and silver sulfate, that are often associated with the determination of chemical oxygen demand (that is, Test Methods D1252). It can also provide a result rapidly, as samples do not require reflux.
1.4Determination of photoelectrochemical oxygen demand in freshwater sources for drinking water treatment plants and treated drinking water matrices has important implications for assessing treatment efficacy. Photoelectrochemical oxygen demand can be used as a bulk surrogate measure of natural organic matter, a key target for drinking water treatment. In aerobic biological treatment processes, determination of photoelectrochemical oxygen demand can provide an estimation of the oxygen required by microorganisms to degrade organic matter. This test method is complementary to existing natural organic matter (NOM) monitoring techniques and will help scientists and engineers further the understanding of NOM in water with a rapid oxygen demand test.
1.5This test method was used successfully with reagent grade water spiked with pure compounds, freshwater sources for drinking water treatment plants and treated drinking water. It is the user’s responsibility to ensure the validity of this test method for waters of untested matrices.
1.6This test method is applicable to oxidizable matter, <50 µm that can be introduced into the sensor.
Note 1:This test method can be performed (1) immediately in the field or laboratory on an unpreserved sample, and (2) in the laboratory on a properly preserved sample following the stated hold times.
1.7The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.
1.9This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D 1193 : 2024 | Standard Specification for Reagent Water |
ASTM D 3370 : 1995 : REV A : R2003 : EDT 1 | Standard Practices for Sampling Water from Closed Conduits |
ASTM D 1129 : 2013 : REDLINE | Standard Terminology Relating to Water |
ASTM D 1129 : 2003 | Standard Terminology Relating to Water |
ASTM D 2777 : 2013 : REDLINE | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 1129 : 2013 | Standard Terminology Relating to Water |
ASTM D 1129 : 2013 : R2020 | Standard Terminology Relating to Water |
ASTM D 5847 : 1999 : REV A : EDT 1 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 2777 : 2012 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 1129 : 2013 : R2020 : EDT 2 | Standard Terminology Relating to Water |
ASTM D 1193 : 1977 : R1983 : EDT 1 | Standard Specification for Reagent Water |
ASTM D 5847 : 2002 : R2007 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 1129 : 2006 | Standard Terminology Relating to Water |
ASTM D 1252 : 1995 | Standard Test Methods for Chemical Oxygen Demand (Dichromate Oxygen Demand) of Water |
ASTM D 2777 : 2003 | Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water |
ASTM D 2777 : 2021 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 3370 : 2010 | Standard Practices for Sampling Water from Closed Conduits |
ASTM D 2777 : 2013 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 5847 : 2002 : R2012 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 1252 : 2006 : R2020 | Standard Test Methods for Chemical Oxygen Demand (Dichromate Oxygen Demand) of Water |
ASTM D 1252 : 2006 : R2012 | Standard Test Methods for Chemical Oxygen Demand (Dichromate Oxygen Demand) of Water |
ASTM D 1252 : 2006 : R2012 : EDT 1 | Standard Test Methods for Chemical Oxygen Demand (Dichromate Oxygen Demand) of Water |
ASTM D 2777 : 1998 | Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water |
ASTM D 1129 : 2013 : R2020 : EDT 1 | Standard Terminology Relating to Water |
ASTM D 3370 : 2008 | Standard Practices for Sampling Water from Closed Conduits |
ASTM D 1129 : 1999 : REV A | Standard Terminology Relating to Water |
ASTM D 1129 : 2006 : REV A | Standard Terminology Relating to Water |
ASTM D 1193 : 2006 : R2011 | Standard Specification for Reagent Water |
ASTM D 1129 : 2024 | Standard Terminology Relating to Water |
ASTM D 5847 : 2002 : R2020 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 1129 : 2003 : REV A | Standard Terminology Relating to Water |
ASTM D 1129 : 2002 | Standard Terminology Relating to Water |
ASTM D 1193 : 1991 | Standard Specification for Reagent Water |
ASTM D 1129 : 2004 | Standard Terminology Relating to Water |
ASTM D 5847 : 2022 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 2777 : 2008 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 2777 : 2006 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 1252 : 2000 | Standard Test Methods for Chemical Oxygen Demand (Dichromate Oxygen Demand) of Water |
ASTM D 3370 : 2018 | Standard Practices for Sampling Water from Flowing Process Streams |
ASTM D 1129 : 2002 : REV A | Standard Terminology Relating to Water |
ASTM D 5847 : 2002 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 3370 : 1976 | Standard Practices for Sampling Water |
ASTM D 1252 : 2006 | Standard Test Methods for Chemical Oxygen Demand (Dichromate Oxygen Demand) of Water |
ASTM D 1193 : 1970 | Standard Specification For Reagent Water |
ASTM D 1193 : 2006 | Standard Specification for Reagent Water |
ASTM D 3370 : 1995 : REV A : R1999 : EDT 1 | Standard Practices for Sampling Water from Closed Conduits |
ASTM D 1193 : 1999 | Standard Specification for Reagent Water |
ASTM D 1129 : 2010 | Standard Terminology Relating to Water |
ASTM D 3370 : 2007 | Standard Practices for Sampling Water from Closed Conduits |
ASTM D 1129 : 2006 : REV A : EDT 1 | Standard Terminology Relating to Water |
ASTM D 1129 : 2001 | Standard Terminology Relating to Water |
ASTM D 1129 : 2004 : EDT 1 | Standard Terminology Relating to Water |
ASTM D 1193 : 2006 : R2018 | Standard Specification for Reagent Water |
ASTM D 2777 : 2008 : EDT 1 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.