• Shopping Cart
    There are no items in your cart

ASTM D 8141 : 2022

Current

Current

The latest, up-to-date edition.

Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Parameters for Modeling of Indoor Environments

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

23-12-2022

€61.92
Excluding VAT

Committee
D 22
DocumentType
Guide
Pages
11
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1This guide is intended to serve as a foundation for understanding when to use emission testing methods designed for volatile organic compounds (VOCs) to determine area-specific emission rates that are typically used in modeling indoor air VOC concentrations and when to use emission testing methods designed for semi-volatile organic compounds (SVOCs) to determine mass transfer emission parameters that are typically used to model indoor air, dust, and surface SVOC concentrations.

1.2This guide discusses how organic chemicals are conventionally categorized with respect to volatility.

1.3This guide presents a simplified mass-transfer model describing organic chemical emissions from a material to bulk air. The values of the model parameters are shown to be specific to material/chemical/chamber combinations.

1.4This guide shows how to use a mass-transfer model to estimate whether diffusion of the chemical within the material or convective mass transfer of the chemical from the surface of the material to the overlying air limits chemical emissions from the material surface.

1.5This guide describes the range of different chambers that are available for emission testing. The chambers are classified as either dynamic or static and either conventional or sandwich. The chambers are categorized as being optimal to determine either the area-specific emission rate or mass-transfer emission parameters.

1.6This guide discusses the roles sorption and convective mass-transfer coefficients play in selecting the appropriate emission chamber and analysis method to accurately and efficiently characterize emissions from indoor materials for use in modeling indoor chemical concentrations.

1.7This guide recommends when to choose an emission test method that is optimized to determine either the area-specific emission rate or mass-transfer emission parameters. For chemicals where the controlling mass-transfer process is unknown, the guide outlines a procedure to determine if the chemical emission is controlled by convective mass transfer of the chemical from the material.

1.8This guide does not provide specific guidance for measuring emission parameters or conducting indoor exposure modeling.

1.9Mechanisms controlling emissions from wet and dry materials and products are different. This guide considers the emission of chemicals from dry materials and products. Examples of functional uses of VOCs and SVOCs that this guide applies to include blowing agents, flame retardants, adhesives, plasticizers, solvents, antioxidants, preservatives, and coalescing agents (1).2 Emission estimations for other VOC and SVOC classes including those generated by incomplete combustion, spray application, or application as a powder (pesticides, termiticides, herbicides, stain repellents, sealants, water repellants) (1) may require different approaches than outlined in this guide because these processes can increase short-term concentrations of chemicals in the air independent of the volatility of the chemical and its categorization as a VVOC (very volatile organic compounds), VOC, SVOC, or NVOC (non-volatile organic compounds).

1.10The effects of the emissions (for example, exposure, and health effects on occupants) are not addressed and are beyond the scope of this guide.

1.11The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.12This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.13This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM D 8345 : 2021 Standard Test Method for Determination of an Emission Parameter for Phthalate Esters and Other Non-Phthalate Plasticizers from Planar Polyvinyl Chloride Indoor Materials for Use in Mass Transfer Modeling Calculations
ASTM D 7911 : 2019 Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test
ASTM D 6803 : 2019 Standard Practice for Testing and Sampling of Volatile Organic Compounds (Including Carbonyl Compounds) Emitted from Architectural Coatings Using Small-Scale Environmental Chambers
ASTM D 8445 : 2022 : REV A Standard Practice for Measuring Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation Samples in a Large-scale Ventilated Enclosure

ASTM D 8142 : 2017 : EDT 1 Standard Test Method for Determining Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation using Micro-Scale Environmental Test Chambers
ASTM D 6177 : 2019 Standard Practice for Determining Emission Profiles of Volatile Organic Chemicals Emitted from Bedding Sets
ASTM D 8142 : 2023 Standard Test Method for Determining Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation using Micro-Scale Environmental Test Chambers
ASTM D 7706 : 2017 Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers
ASTM D 6177 : 2019 : R2024 Standard Practice for Determining Emission Profiles of Volatile Organic Chemicals Emitted from Bedding Sets
ASTM D 7706 : 2017 : R2023 Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.