ASTM E 1039 : 1999

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Standard Test Method for Calibration of Silicon Non-Concentrator Photovoltaic Primary Reference Cells Under Global Irradiation (Withdrawn 2004)

Available format(s)

Hardcopy , PDF

Withdrawn date

05-11-2013

Language(s)

English

Published date

31-12-2010

€59.22
Excluding VAT

CONTAINED IN VOL. 12.02, 2001 Specifies procedure for calibration and characterization of primary terrestrial, silicon photovoltaic reference cells to the global reference spectral irradiance distribution specified by Tables E 892. Recommended physical requirements are outlined in E 1040. Reference cells are mainly used to determine electrical performance of a photovoltaic device. Calibration takes place outdoors in natural sunlight by reference to a pyranometer used for measuring global irradiance.

Committee
E 44
DocumentType
Test Method
Pages
4
PublisherName
American Society for Testing and Materials
Status
Withdrawn

1.1 This test method is intended to be used for calibration and characterization of primary terrestrial, silicon photovoltaic reference cells to the global reference spectral irradiance distribution defined by Tables E892. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device.

1.2 Primary global reference cells are calibrated outdoors in natural sunlight by reference to a pyranometer that is used to measure the global irradiance.

1.3 This test method applies only to the calibration of a photovoltaic cell which demonstrates a linear short-circuit current versus irradiance characteristic over its intended range of use, as defined in Test Method E1143.

1.4 This test method applies only to the calibration of single- or poly-crystalline silicon reference cells that have been fabricated with a single photovoltaic junction.

1.5 There is no similar or equivalent ISO standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E 973M : 1996 Standard Test Method for Determination of the Spectral Mismatch Parameter Between a Photovoltaic Device and a Photovoltaic Reference Cell [Metric] (Withdrawn 2005)
ASTM E 1036M : 1996 : EDT 2 Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells (Withdrawn 2005)

ASTM E 1328 : 2005 Standard Terminology Relating to Photovoltaic Solar Energy Conversion (Withdrawn 2012)
ASTM E 772 : 2015 : REDLINE Standard Terminology of Solar Energy Conversion
ASTM E 1125 : 2016 : REDLINE Standard Test Method for Calibration of Primary Non-Concentrator Terrestrial Photovoltaic Reference Cells Using a Tabular Spectrum
ASTM E 948 : 2016 : REDLINE Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.