• Shopping Cart
    There are no items in your cart

ASTM E 1105 : 2000 : R2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Superseded by

ASTM E 1105 : 2015

Language(s)

English

Published date

01-04-2008

€67.30
Excluding VAT

Committee
E 06
DocumentType
Test Method
Pages
6
ProductNote
Reconfirmed 2008
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This test method covers the determination of the resistance of installed exterior windows, curtain walls, skylights, and doors to water penetration when water is applied to the outdoor face and exposed edges simultaneously with a static air pressure at the outdoor face higher than the pressure at the indoor face.

1.2 This test method is applicable to any curtain-wall area or to windows, skylights, or doors alone. It is intended primarily for determining the resistance to water penetration through such assemblies for compliance with specified performance criteria, but it may also be used to determine the resistance to penetration through the joints between the assemblies and the adjacent construction. Other procedures may be appropriate to identify sources of leakage.

1.3 This test method addresses water penetration through a manufactured assembly. Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. This test method does not address these issues.

1.4 The proper use of this test method requires a knowledge of the principles of pressure measurement.

1.5 The values stated in SI units are to be regarded as the standard. The inch-pound equivalents of SI units may be approximate.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 7.1.

ASTM E 2128 : 2017 Standard Guide for Evaluating Water Leakage of Building Walls
ASTM E 2813 : 2018 Standard Practice for Building Enclosure Commissioning
ASTM D 7338 : 2014 Standard Guide for Assessment Of Fungal Growth in Buildings
ASTM E 2351 : 2004 : REV A : R2013 Standard Guide for Specifying and Evaluating Performance of Single Family Attached and Detached Dwellings—Functionality (Withdrawn 2022)
ASTM E 2112 : 2019 : REV B Standard Practice for Installation of Exterior Windows, Doors and Skylights
ASTM E 2266 : 2011 Standard Guide for Design and Construction of Low-Rise Frame Building Wall Systems to Resist Water Intrusion
ASTM C 1401 : 2014 Standard Guide for Structural Sealant Glazing
ASTM E 241 : 2009 : R2014 : EDT 1 Standard Guide for Limiting Water-Induced Damage to Buildings

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.