• Shopping Cart
    There are no items in your cart

ASTM E 1153 : 2014 : EDT 1

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Efficacy of Sanitizers Recommended for Inanimate, Hard, Nonporous Non-Food Contact Surfaces

Available format(s)

Hardcopy , PDF

Superseded date

05-11-2022

Superseded by

ASTM E 1153 : 2022

Language(s)

English

Published date

29-06-2020

€49.35
Excluding VAT

Committee
E 35
DocumentType
Test Method
Pages
6
ProductNote
ε1 NOTE—Section 13.3.2 was editorially corrected in June 2020.
This standard is also refers to 40 CFR,Part 160.
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This test method is used to evaluate the antimicrobial efficacy of sanitizers on precleaned, inanimate, hard, nonporous, non-food contact surfaces against Staphylococcus aureus, or Klebsiella pneumoniae or Enterobacter aerogenes, or a combination thereof. Appropriate modifications to the method may be required when testing organisms not specified herein. When utilizing test surfaces not described herein (see Test Method E2274) or when evaluating spray-based or towelette-based antimicrobial products, modifications may also be required.

1.2This test method may also be used to evaluate the antimicrobial efficacy of one-step cleaner-sanitizer formulations recommended for use on lightly soiled, inanimate, nonporous, non-food contact surfaces.

1.3It is the responsibility of the investigator to determine whether Good Laboratory Practices (GLP) are required and to follow them where appropriate (see section 40 CFR, 160 or as revised.)

1.4The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5This standard may involve hazardous materials, chemicals and microorganisms and should be performed only by persons who have had formal microbiological training. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM E 3135 : 2018 Standard Practice for Determining Antimicrobial Efficacy of Ultraviolet Germicidal Irradiation Against Microorganisms on Carriers with Simulated Soil
ASTM E 1053 : 2020 Standard Practice to Assess Virucidal Activity of Chemicals Intended for Disinfection of Inanimate, Nonporous Environmental Surfaces
ASTM E 3286 : 2021 Standard Practice for Preparation Of Cell Monolayers on Glass Surfaces for Evaluation of Microbicidal Properties of Non-Chemical Based Antimicrobial Treatment Technologies

ASTM E 1054 : 2021 : EDT 1 Standard Practices for Evaluation of Inactivators of Antimicrobial Agents
ASTM E 1054 : 2008 : R2013 Standard Test Methods for Evaluation of Inactivators of Antimicrobial Agents
ASTM E 1054 : 2021 Standard Test Practices for Evaluation of Inactivators of Antimicrobial Agents

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.