CONTAINED IN VOLUME 03.05, 2001 Defines test requirements for the chemical analysis of titanium and titanium alloys.
Committee |
E 01
|
DocumentType |
Test Method
|
PublisherName |
American Society for Testing and Materials
|
Status |
Withdrawn
|
1.1 These test methods cover procedures for the chemical analysis of titanium and titanium alloys containing the following elements in the concentration ranges listed:
Element Concentration Range, % Aluminum 1 to 10 Chloride 0.02 to 1.0 Chromium 0.005 to 20 Columbium 0.25 to 5.0 Copper 0.001 to 1.1 Iron 0.005 to 20 Magnesium 0.02 to 1.0 Manganese 0.005 to 20 Molybdenum 0.005 to 5 Nitrogen 0.005 to 0.20 Oxygen 0.03 to 0.50 Palladium 0.10 to 0.25 Silicon 0.005 to 5.0 Tantalum 0.25 to 5.0 Tin 0.25 to 10 Tungsten 0.005 to 1.0 Vanadium 0.5 to 20 Zirconium 1.0 to 201.2 The test methods in this standard are contained in the sections indicated as follows:
Sections Aluminum: 8-Quinolinol (Gravimetric) Test Method 2 8 to 14 Chloride by the Gravimetric Test Method 2 15 to 22 Copper: Cuprizone (Photometric) Test Method 23 to 32 Diethyldithiocarbamate (Photometric) Test Method 33 to 42 Manganese: Periodate (Photometric) Test Method 43 to 52 Molybdenum Thiocyanate-Extraction (Photometric) Test Method 53 to 62 Thiocyanate 2-(2-Butoxyethoxy) Ethanol (Photometric) Test Method 63 to 72 Nitrogen by the Distillation-Titration Test Method 2 73 to 80 Palladium by the 1-Nitroso-2-Naphthol (Photometric) Test 81 to 90 Method Vanadium by the Potassium Permanganate (Titrimetric) Test 91 to 97 Method Zirconium by the Mandelic Acid (Gravimetric) Test Method 98 to 1041.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
SAE AMS T 81556 : 2001 | TITANIUM AND TITANIUM ALLOYS, EXTRUDED BARS AND SHAPES, AIRCRAFT QUALITY |
SAE AMS 4962 : 2016 | TITANIUM ALLOY, INVESTMENT CASTINGS, 6 AL - 4 V HOT ISOSTATICALLY PRESSED |
MIL-U-46126 Base Document:1968 | URANIUM ALLOY FOR BODY SECTION CENTER OF AMMUNITION COMPONENTS |
ASTM F 468M : 2006 : EDT 1 | Standard Specification for Nonferrous Bolts, Hex Cap Screws, and Studs for General Use [Metric] |
ASTM F 468M : 2006 : R2012 | Standard Specification for Nonferrous Bolts, Hex Cap Screws, and Studs for General Use (Metric) |
MIL-T-81556 Revision A:1983 | TITANIUM & TITANIUM ALLOYS, EXTRUDED BARS AND SHAPES, AIRCRAFT QUALITY |
MIL-B-87114 Revision A:1978 | BOLTS, RECESS DRIVE, GENERAL SPECIFICATION FOR |
MIL-R-83459 Revision A:1978 | RIVET, TITANIUM, BIMETAL 95 KSI F SU GENERAL SPECIFICATION FOR |
15/30284685 DC : 0 | BS ISO 18762 - TUBES OF TITANIUM AND TITANIUM ALLOYS - WELDED TUBES FOR CONDENSERS AND HEAT EXCHANGERS - TECHNICAL DELIVERLY CONDITIONS |
ASTM F 1108 : 2014 : REDLINE | Standard Specification for Titanium-6Aluminum-4Vanadium Alloy Castings for Surgical Implants (UNS R56406) |
BS ISO 18762:2016 | Tubes of titanium and titanium alloys. Welded tubes for condensers and heat exchangers. Technical delivery conditions |
ASTM F 468M:2006 | Standard Specification for Nonferrous Bolts, Hex Cap Screws, and Studs for General Use [Metric] |
NASA MSFC SPEC 469 : 1968 | TITANIUM AND TITANIUM ALLOYS, HEAT TREATMENT OF |
ASTM F 561 : 2013 | Standard Practice for Retrieval and Analysis of Medical Devices, and Associated Tissues and Fluids |
SAE AMS 4997 : 1977 | TITANIUM ALLOY POWDER 5AL - 2SN - 2ZR - 4CR - 4MO - 0.100 PREMIUM QUALITY |
ASTM A 845 : 1985 : R2000 | Standard Specification for Titanium Scrap for Use in Deoxidation and Alloying of Steel (Withdrawn 2005) |
MIL-T-9046 Revision J:1983 | TITANIUM AND TITANIUM ALLOY, SHEET, STRIP AND PLATE |
ASTM F 3042 : 2013 | Standard Specification for Nonferrous Hex Socket, Slotted Headless, and Square Head Set Screws |
SAE AMS T 9046 : 2006 | TITANIUM AND TITANIUM ALLOY, SHEET, STRIP, AND PLATE |
SAE MAM 4911 : 1994 | TITANIUM ALLOY, SHEET, STRIP, AND PLATE, 6AL - 4V, ANNEALED |
ASTM F 467M : 2006 : REV A : EDT 1 | Standard Specification for Nonferrous Nuts for General Use [Metric] |
MIL U 46045 : D | URANIUM ALLOY, WROUGHT, BARS, BILLETS, AND TUBULAR SHAPES |
ASTM F 467M : 2006 : REV A : R2012 | Standard Specification for Nonferrous Nuts for General Use (Metric) |
MIL-DTL-46077 Revision G:2006 | ARMOR PLATE, TITANIUM ALLOY, WELDABLE |
ISO 18762:2016 | Tubes of titanium and titanium alloys Welded tubes for condensers and heat exchangers Technical delivery conditions |
ASTM F 1341 : 1999 | Standard Specification for Unalloyed Titanium Wire UNS R50250, UNS R50400, UNS R50550, UNS R50700, for Surgical Implant Applications (Withdrawn 2006) |
SAE AMS4908G | TITANIUM ALLOY, SHEET AND STRIP 8MN ANNEALED, 110 KSI (758 MPA) YIELD STRENGTH |
ASTM F 467M : 2006 : REV A : EDT 2 | Standard Specification for Nonferrous Nuts for General Use (Metric) |
MIL-T-24766 Base Document:1992 | TITANIUM FORGINGS & FORGING STOCK, HIGH QUALITY FOR SHIPS SERVICE |
AWS A5.16/A5.16M : 2013 | SPECIFICATION FOR TITANIUM AND TITANIUM-ALLOY WELDING ELECTRODES AND RODS |
ASTM E 50 : 2017 : REDLINE | Standard Practices for Apparatus, Reagents, and Safety Considerations for Chemical Analysis of Metals, Ores, and Related Materials |
ASTM E 173 : 1993 | Practice for Conducting Interlaboratory Studies of Methods for Chemical Analysis of Metals (Withdrawn 1997) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.