• Shopping Cart
    There are no items in your cart

ASTM E 1362 : 2015

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Methods for Calibration of Non-Concentrator Photovoltaic Non-Primary Reference Cells

Available format(s)

Hardcopy , PDF

Superseded date

02-09-2020

Language(s)

English

Published date

01-12-2015

€67.30
Excluding VAT

These test methods cover calibration and characterization of non-primary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution.

Committee
E 44
DocumentType
Test Method
Pages
6
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1These test methods cover calibration and characterization of non-primary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device.

1.2Non-primary reference cells are calibrated indoors using simulated sunlight or outdoors in natural sunlight by reference to a previously calibrated reference cell, which is referred to as the calibration source device.

1.2.1The non-primary calibration will be with respect to the same reference spectral irradiance distribution as that of the calibration source device.

1.2.2The calibration source device may be a primary reference cell calibrated in accordance with Test Method E1125, or a non-primary reference cell calibrated in accordance with these test methods.

1.2.3For the special case in which the calibration source device is a primary reference cell, the resulting non-primary reference cell is also referred to as a secondary reference cell.

1.3Non-primary reference cells calibrated according to these test methods will have the same radiometric traceability as that of the calibration source device. Therefore, if the calibration source device is traceable to the World Radiometric Reference (WRR, see Test Method E816), the resulting secondary reference cell will also be traceable to the WRR.

1.4These test methods apply only to the calibration of a photovoltaic cell that demonstrates a linear short-circuit current versus irradiance characteristic over its intended range of use, as defined in Test Method E1143.

1.5These test methods apply only to the calibration of a photovoltaic cell that has been fabricated using a single photovoltaic junction.

1.6The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E 973 : 2016 Standard Test Method for Determination of the Spectral Mismatch Parameter Between a Photovoltaic Device and a Photovoltaic Reference Cell
ASTM E 948 : 2016 Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight
ASTM E 772 : 2015 Standard Terminology of Solar Energy Conversion
ASTM E 1040 : 2010 : R2016 Standard Specification for Physical Characteristics of Nonconcentrator Terrestrial Photovoltaic Reference Cells
ASTM E 927 : 2019 Standard Classification for Solar Simulators for Electrical Performance Testing of Photovoltaic Devices
ASTM E 1125 : 2016 Standard Test Method for Calibration of Primary Non-Concentrator Terrestrial Photovoltaic Reference Cells Using a Tabular Spectrum
ASTM E 2236 : 2010 : R2019 Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules
ASTM E 1021 : 2015 : R2019 Standard Test Method for Spectral Responsivity Measurements of Photovoltaic Devices
ASTM E 1036 : 2015 : R2019 Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells
ASTM E 2848 : 2013 : R2018 Standard Test Method for Reporting Photovoltaic Non-Concentrator System Performance

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.