• Shopping Cart
    There are no items in your cart

ASTM E 1474 : 2020 : REV A : REDLINE

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Determining the Heat Release Rate of Upholstered Furniture and Mattress Components or Composites Using a Bench Scale Oxygen Consumption Calorimeter

Available format(s)

PDF , Hardcopy Redline , PDF Redline

Superseded date

21-01-2022

Language(s)

English

Published date

01-02-2020

€74.48
Excluding VAT

Committee
E 05
DocumentType
Redline
Pages
15
ProductNote
THIS STANDARD IS ALSO REFERS TO CA TB 133
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This fire-test-response test method can be used to determine the ignitability and heat release from the composites of contract, institutional, or high-risk occupancy upholstered furniture or mattresses using a bench scale oxygen consumption calorimeter.

1.2This test method provides for measurement of the time to sustained flaming, heat release rate, peak and total heat release, and effective heat of combustion at a constant initial test heat flux of 35 kW/m2. This test method is also suitable to obtain heat release data at different heating fluxes. The specimen is oriented horizontally, and a spark ignition source is used.

1.3The times to sustained flaming, heat release, and effective heat of combustion are determined using the apparatus and procedures described in Test Method E1354.

1.4The tests are performed on bench-scale specimens combining the furniture or mattress outer layer components. Frame elements are not included.

1.5The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.6This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6.

1.8Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

1.9This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Access your standards online with a subscription