ASTM E 1502 : 2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Guide for Use of Fixed-Point Cells for Reference Temperatures
Hardcopy , PDF
27-11-2024
English
09-09-2016
Committee |
E 20
|
DocumentType |
Guide
|
Pages |
12
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This guide describes the essential features of fixed-point cells and auxiliary apparatus, and the techniques required to realize fixed points in the temperature range from 29 to 1085°C.3
1.2Design and construction requirements of fixed-point cells are not addressed in this guide. Typical examples are given in Figs. 1 and 2.
Note 1:This example shows an insulated furnace body and two alternative types of furnace cores. The core on the left is a three-zone shielded type. The core on the right employs a heat pipe to reduce temperature gradients.
1.3This guide is intended to describe good practice and establish uniform procedures for the realization of fixed points.
1.4This guide emphasizes principles. The emphasis on principles is intended to aid the user in evaluating cells, in improving technique for using cells, and in establishing procedures for specific applications.
1.5For the purposes of this guide, the use of fixed-point cells for the accurate calibration of thermometers is restricted to immersion-type thermometers that, when inserted into the reentrant well of the cell, (1) indicate the temperature only of the isothermal region of the well, and (2) do not significantly alter the temperature of the isothermal region of the well by heat transfer.
1.6This guide does not address all of the details of thermometer calibration.
1.7This guide is intended to complement special operating instructions supplied by manufacturers of fixed-point apparatus.
1.8The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.9The following hazard caveat pertains only to the test method portion, Section 7, of this guide. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 2593 : 2017 | Standard Guide for Accuracy Verification of Industrial Platinum Resistance Thermometers |
ASTM E 644 : 2011 | Standard Test Methods for Testing Industrial Resistance Thermometers |
ASTM E 344 : 2020 | Terminology Relating to Thermometry and Hydrometry |
ASTM E 644 : 2011(R2019) | Standard Test Methods for Testing Industrial Resistance Thermometers |
ASTM E 879 : 2020 | Standard Specification for Thermistor Sensors for General Purpose and Laboratory Temperature Measurements |
ASTM E 344 : 2018 | Terminology Relating to Thermometry and Hydrometry |
ASTM E 344 : 2001 : REV A | Terminology Relating to Thermometry and Hydrometry |