• Shopping Cart
    There are no items in your cart

ASTM E 1529 : 2014 : REV A

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies

Available format(s)

Hardcopy , PDF

Superseded date

29-12-2014

Superseded by

ASTM E 1529 : 2016

Language(s)

English

Published date

15-12-2014

€96.91
Excluding VAT

Committee
E 05
DocumentType
Test Method
Pages
25
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1The test methods described in this fire-test-response standard are used for determining the fire-test response of columns, girders, beams or similar structural members, and fire-containment walls, of either homogeneous or composite construction, that are employed in HPI or other facilities subject to large hydrocarbon pool fires.

1.2It is the intent that tests conducted in accordance with these test methods will indicate whether structural members of assemblies, or fire-containment wall assemblies, will continue to perform their intended function during the period of fire exposure. These tests shall not be construed as having determined suitability for use after fire exposure.

1.3These test methods prescribe a standard fire exposure for comparing the relative performance of different structural and fire-containment wall assemblies under controlled laboratory conditions. The application of these test results to predict the performance of actual assemblies when exposed to large pool fires requires a careful engineering evaluation.

1.4These test methods provide for quantitative heat flux measurements during both the control calibration and the actual test. These heat flux measurements are being made to support the development of design fires and the use of fire safety engineering models to predict thermal exposure and material performance in a wide range of fire scenarios.

1.5These test methods are useful for testing other items such as piping, electrical circuits in conduit, floors or decks, and cable trays. Testing of these types of items requires development of appropriate specimen details and end-point or failure criteria. Such failure criteria and test specimen descriptions are not provided in these test methods.

1.6Limitations—These test methods do not provide the following:

1.6.1Full information on the performance of assemblies constructed with components or of dimensions other than those tested.

1.6.2An evaluation of the degree to which the assembly contributes to the fire hazard through the generation of smoke, toxic gases, or other products of combustion.

1.6.3Simulation of fire behavior of joints or connections between structural elements such as beam-to-column connections.

1.6.4Measurement of flame spread over the surface of the test assembly.

1.6.5Procedures for measuring the test performance of other structural shapes (such as vessel skirts), equipment (such as electrical cables, motor-operated valves, etc.), or items subject to large hydrocarbon pool fires, other than those described in 1.1.

1.6.6The erosive effect that the velocities or turbulence, or both, generated in large pool fires has on some fire protection materials.

1.6.7Full information on the performance of assemblies at times less than 5 min because the rise time called out in Section 5 is longer than that of a real fire.

1.7These test methods do not preclude the use of a real fire or any other method of evaluating the performance of structural members and assemblies in simulated fire conditions. Any test method that is demonstrated to comply with Section 5 is acceptable.

1.8The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.9This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

1.10This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.11The text of this standard references notes and footnotes which provide explanatory information. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

ASTM E 3057 : 2019 Standard Test Method for Measuring Heat Flux Using Directional Flame Thermometers with Advanced Data Analysis Techniques
ASTM D 7746 : 2011 : R2016 Standard Practice for Calculating the Superimposed Load on Wood-frame Floor-Ceiling Assemblies for Standard Fire-Resistance Tests
ASTM E 1966 : 2015 : R2019 Standard Test Method for Fire-Resistive Joint Systems
ASTM E 2749 : 2015 : REV A : R2019 Standard Practice for Measuring the Uniformity of Furnace Exposure on Test Specimens
ASTM E 2837 : 2013 : R2017 Standard Test Method for Determining the Fire Resistance of Continuity Head-of-Wall Joint Systems Installed Between Rated Wall Assemblies and Nonrated Horizontal Assemblies
ASTM E 2874 : 2019 Standard Test Method for Determining the Fire-Test Response Characteristics of a Building Spandrel-Panel Assembly Due to External Spread of Fire
ASTM E 2748 : 2012 : REV A : R2017 Standard Guide for Fire-Resistance Experiments
ASTM E 2307 : 2019 Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using Intermediate-Scale, Multi-story Test Apparatus
ASTM E 1725 : 2019 Standard Test Methods for Fire Tests of Fire-Resistive Barrier Systems for Electrical System Components
ASTM E 3157 : 2019 Standard Guide for Understanding and Using Information Related to Installation of Firestop Systems
ASTM D 6513 : 2014 Standard Practice for Calculating the Superimposed Load on Wood-frame Walls for Standard Fire-Resistance Tests
ASTM E 176 : 2018 : REV A Standard Terminology of Fire Standards
ASTM F 1387 : 1999 : R2012 Standard Specification for Performance of Piping and Tubing Mechanically Attached Fittings
ASTM F 1173 : 2001 : R2018 Standard Specification for Thermosetting Resin Fiberglass Pipe Systems to Be Used for Marine Applications

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.