Standard Guide for Conducting Short-Term Chronic Toxicity Tests with Echinoid Embryos

Available format(s)

Hardcopy , PDF

Superseded date

28-01-2022

Language(s)

English

Published date

11-02-2021

€96.91
Excluding VAT

Committee
E 50
DocumentType
Guide
Pages
23
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This guide covers procedures for obtaining laboratory data concerning the short-term chronic effects of a test material on echinoderm embryos and the resulting larvae (sea urchins and sand dollars) during static 48- to 96-h exposures. These procedures have generally been used with U.S. East Coast (Arbacia punctulata and Strongylocentrotus droebachiensis ) (1)3 and West Coast species (Strongylocentrotus purpuratus, S. droebachiensis, and Dendraster excentricus) (2). The basic procedures described in this guide first originated in Japan and Scandanavia (3), and parallel procedures have been used with foreign species, especially in Japan and the Mediterranean (4). These procedures will probably be useful for conducting static toxicity tests with embryos of other echinoid species, although modifications might be necessary.

1.2Other modifications of these procedures might be justified by special needs or circumstances. Although using procedures appropriate to a particular species or special needs and circumstances is more important than following prescribed procedures, the results of tests conducted by using unusual procedures are not likely to be comparable with those of many other tests. The comparison of results obtained by using modified and unmodified versions of these procedures might provide useful information concerning new concepts and procedures for conducting tests starting with embryos of echinoids.

1.3These procedures are applicable to most chemicals, either individually or in formulations, commercial products, or known mixtures. With appropriate modifications, these procedures can be used to conduct tests on temperature, dissolved oxygen, and pH and on such materials as aqueous effluents (see also Guide E1192), leachates, oils, particulate matter, surface waters, effluents, and sediments (Annex A1). Renewal tests might be preferable to static tests for materials that have a high oxygen demand, are highly volatile, are rapidly transformed biologically or chemically in aqueous solution, or are removed from test solutions in substantial quantities by the test chambers or organisms during the test.

1.4Results of short-term chronic toxicity tests with echinoid embryos should usually be reported as the 50 % effect concentration (EC50) based on the total abnormally developed embryos and larvae. In some situations, it might only be necessary to determine whether a specific concentration is toxic to embryos or whether the EC50 is above or below a specific concentration.

1.5This guide is arranged as follows:

Section

Scope

1

Referenced Documents

2

Terminology

3

Summary of Guide

4

Significance and Use

5

Apparatus

6

 Facilities

6.1

 Construction Materials

6.2

 Test Chambers

6.3

 Cleaning

6.4

 Acceptability

6.5

Safety Precautions

7

Dilution Water

8

 Requirements

8.1

 Source

8.2

 Treatment

8.3

 Characterization

8.4

Test Material

9

 General

9.1

 Stock Solution

9.2

 Test Concentration(s)

9.3

Test Organisms

10

 Species

10.1

 Age

10.2

 Source of Embryos

10.3

 Handling

10.4

 Test Animal Source and Condition

10.5

 Spawning and Fertilization

10.6

 Quality

10.7

Procedure

11

 Experimental Design

11.1

 Dissolved Oxygen

11.2

 Temperature

11.3

 Beginning the Test

11.4

 Feeding

11.5

 Duration of Test

11.6

 Biological Data

11.7

 Control Performance

11.8

 Other Measurements

11.9

Analytical Methods

12

Acceptability of Test

13

Calculation of Results

14

Report

15

Keywords

16

Annex

 Sediment Tests

Annex A1

1.6The values stated in SI units are to be regarded as the standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations. Specific precautionary statements are given in Section 7.

1.8This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM E 1525 : 2002 : R2014 Standard Guide for Designing Biological Tests with Sediments
ASTM E 1850 : 2004 : R2019 Standard Guide for Selection of Resident Species as Test Organisms for Aquatic and Sediment Toxicity Tests
ASTM E 729 : 1996 : R2014 Standard Guide for Conducting Acute Toxicity Tests on Test Materials with Fishes, Macroinvertebrates, and Amphibians

ASTM E 1525 : 1994 Standard Guide for Designing Biological Tests with Sediments
ASTM E 724 : 1998 : R2012 Standard Guide for<brk type="line"/> Conducting Static Acute Toxicity Tests Starting with Embryos of Four Species of Saltwater Bivalve Molluscs
ASTM E 1706 : 2000 : EDT 1 Test Method for Measuring the Toxicity of Sediment-Associated Contaminants with Fresh Water Invertebrates
ASTM E 1391 : 1994 Standard Guide for Collection, Storage, Characterization, and Manipulation of Sediments for Toxicological Testing
ASTM E 724 : 2021 Standard Guide for<brk type="line"/> Conducting Static Short-Term Chronic Toxicity Tests Starting with Embryos of Four Species of Saltwater Bivalve Molluscs

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.