ASTM E 1740 : 2015 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Determining the Heat Release Rate and Other Fire-Test-Response Characteristics of Wall Covering or Ceiling Covering Composites Using a Cone Calorimeter
14-04-2020
English
01-04-2015
CONTAINED IN VOL. 04.07, 2015 Describes the ignitability and heat release rate of composites consisting of a wallcovering, a substrate, and all laminating adhesives, coatings, and finishes.
Committee |
E 05
|
DocumentType |
Redline
|
Pages |
14
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This fire-test-response test method covers determination of the ignitability and heat release rate of composites consisting of a wall covering or ceiling covering, a substrate, and all laminating adhesives, coatings, and finishes. Heat release information cannot be used alone to evaluate the flammability of wall coverings or ceiling coverings. The data are intended to be used for modeling or with other data to evaluate a material.
1.2This test method provides for measurement of the time to sustained flaming, heat release rate, peak and total heat release, and effective heat of combustion at a constant initial test heat flux of 35 kW/m2. Heat release data at different heat fluxes are also obtained by this test method. The specimen is oriented horizontally, and a spark ignition source is used.
1.3The fire-test-response characteristics are determined using the apparatus and procedures described in Test Method E1354.
1.4The tests are conducted on bench-scale specimens combining the components used in the actual installation.
1.5The values stated in SI units are to be regarded as the standard. See IEEE/ASTM SI-10.
1.6Fire testing of products and materials is inherently hazardous, and adequate safeguards for personnel and property shall be used in conducting these tests. This test method potentially involves hazardous materials, operations, and equipment.
1.7This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.
1.8Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests. Specific information about hazard is given in Section 6.
1.9This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM F 2116 : 2001 : R2015 | Standard Specification for Low Stretch and Static Kernmantle Life Safety Rope (Withdrawn 2024) |
NFPA 555 : 2017 | METHODS FOR EVALUATING POTENTIAL FOR ROOM FLASHOVER |
ASTM E 2280 : 2017 : REDLINE | Standard Guide for Fire Hazard Assessment of the Effect of Upholstered Seating Furniture Within Patient Rooms of Health Care Facilities |
ASTM F 2116 : 2001 : R2007 | Standard Specification for Low Stretch and Static Kernmantle Life Safety Rope |
ASTM E 2102 : 2017 : REDLINE | Standard Test Method for Measurement of Mass Loss and Ignitability for Screening Purposes Using a Conical Radiant Heater |
ASTM E 2707 : 2015 : REDLINE | Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure |
ASTM F 2116 : 2001 | Standard Specification for Low Stretch and Static Kernmantle Life Safety Rope |
ASTM E 2067 : 2015 : REDLINE | Standard Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests |
ASTM E 603 : 2017 : REDLINE | Standard Guide for Room Fire Experiments |
ISO 5660-1:2015 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement) |
ISO 13943:2017 | Fire safety — Vocabulary |
ASTM E 906 : 2009 | Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method |
ASTM D 5865 : 2013 : REDLINE | TEST METHOD FOR GROSS CALORIFIC VALUE OF COAL AND COKE |
IEEE/ASTM SI_10-2010 | American National Standard for Metric Practice |
ASTM E 1474 : 2014 : REDLINE | Standard Test Method for Determining the Heat Release Rate of Upholstered Furniture and Mattress Components or Composites Using a Bench Scale Oxygen Consumption Calorimeter |
ISO 4880:1997 | Burning behaviour of textiles and textile products — Vocabulary |
NFPA 265 : 2015 | METHODS OF FIRE TESTS FOR EVALUATING ROOM FIRE GROWTH CONTRIBUTION OF TEXTILE OR EXPANDED VINYL WALL COVERINGS ON FULL HEIGHT PANELS AND WALLS |
NFPA 286 : 2015 | STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH |
ASTM E 1354 : 2017 : REDLINE | Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.