• There are no items in your cart

ASTM E 1851 : 2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Electromagnetic Shielding Effectiveness of Durable Rigid Wall Relocatable Structures

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Superseded by

ASTM E 1851 : 2015

Language(s)

English

Published date

01-11-2009

€74.48
Excluding VAT

Committee
E 06
DocumentType
Test Method
Pages
16
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This test method covers the determination of the electromagnetic shielding effectiveness of durable relocatable shielded enclosures.

1.1.1 The intended application of this test method is for virgin shielded enclosures that do not have any equipment or equipment racks. It is recommended that tests be conducted before the interior finish work begins. However, the shield assembly including all enclosure penetrations shall be completed and required penetration protection devices shall be installed in accordance with the design specification. The test method can also be used on existing shielded enclosures after repair work is done to verify workmanship, but it may be necessary to remove equipment or equipment racks to gain access to a test area.

1.1.2 The test procedures delineated in this document are comprehensive and may require several days to complete for a room-size shielded enclosure. A user can apply this test method for a first article test that requires proof of concept and validation of design and fabrication technique. Appendix X2 provides guidance on choosing test points so shielding effectiveness tests on a room-size shielded enclosure may be completed in about one-half day for which it applies to shielded enclosures coming off an assembly line.

1.2 This test method is for use in the following frequency ranges: 140 to 160 kHz, 14 to 16 MHz, 300 to 500 MHz, 900 to 1000 MHz, and 8.5 to 10.5 GHz. Specific test frequencies within these ranges are required (see 10.1.1 and 10.2.1). Additional measurements in the range of 10 kHz to 10.1.5.1 GHz may be performed. For specific applications, the frequency range may be extended from 50 Hz to 40 GHz. Appendix X1 provides guidance on selecting measurement frequencies.

1.3 This test method is not applicable to individual components such as separate walls, floors, ceilings, or shielded racks.

1.4 This standard may involve hazardous materials, operations, equipment, or any combination.

1.5 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

X2.1.1 The test methods described in this appendix can be used to verify quality of workmanship of shielded enclosures coming off an assembly line. It is presumed that a first article of the shielded enclosure has been tested to verify its design concept in accordance with the procedures specified in the main text of this standard and that the shielded enclosure passed a shielding effectiveness test. Test methods specified in this appendix are considered a reasonably cost effective means of verifying quality of workmanship of a shielded enclosure.

X2.1.1.1 As specified in 1.1 of the main text, the intended application of the test methods is for shielded enclosures that do not have equipment or equipment racks. It is recommended that tests be conducted before the interior finish work begins. However, the shield assembly including all enclosure penetrations shall be completed, and penetration protection devices shall be installed in accordance with the design specification if required.

X2.1.2 These test methods are not applicable to individual components such as separate walls, floors, ceilings, or shielded racks.

X2.1.3 Test methods described in this appendix may involve hazardous materials, operations, and equipment. It is the responsibility of the user of this appendix to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

X2.1.4 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.

ASTM E 1925 : 2018 Specification for Engineering and Design Criteria for Rigid Wall Relocatable Structures
ASTM E 1975 : 2018 Standard Specification for Shelter, Electrical, Equipment S-280/G
ASTM E 2377 : 2018 Standard Specification for Shelter, Electrical Equipment, Lightweight