• Shopping Cart
    There are no items in your cart

ASTM E 1931 : 2016 : R2022

Current

Current

The latest, up-to-date edition.

Standard Guide for Non-computed X-Ray Compton Scatter Tomography

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

06-07-2022

€61.92
Excluding VAT

Committee
E 07
DocumentType
Guide
Pages
14
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1Purpose—This guide covers a tutorial introduction to familiarize the reader with the operational capabilities and limitations inherent in a single non-computed X-ray Compton Scatter Tomography (CST). Also included is a brief description of the physics and typical hardware configuration for CST. This single technique is still used for a small number of inspections. This is not meant as comprehensive guide covering the variety of Compton scattering techniques that are now used for non-destructive testing and security screen screening.

1.2Advantages—X-ray Compton Scatter Tomography (CST) is a radiologic nondestructive examination method with several advantages that include:

1.2.1The ability to perform X-ray examination without access to the opposite side of the examination object;

1.2.2The X-ray beam need not completely penetrate the examination object allowing thick objects to be partially examined. Thick examination objects become part of the radiation shielding thereby reducing the radiation hazard;

1.2.3The ability to examine and image object subsurface features with minimal influence from surface features;

1.2.4The ability to obtain high-contrast images from low subject contrast materials that normally produce low-contrast images when using traditional transmitted beam X-ray imaging methods; and

1.2.5The ability to obtain depth information of object features thereby providing a three-dimensional examination. The ability to obtain depth information presupposes the use of a highly collimated detector system having a narrow angle of acceptance.

1.3Applications—This guide does not specify which examination objects are suitable, or unsuitable, for CST. As with most nondestructive examination techniques, CST is highly application specific thereby requiring the suitability of the method to be first demonstrated in the application laboratory. This guide does not provide guidance in the standardized practice or application of CST techniques. No guidance is provided concerning the acceptance or rejection of examination objects examined with CST.

1.4Limitations—As with all nondestructive examination methods, CST has limitations and is complementary to other NDE methods. Chief among the limitations is the difficulty in performing CST on thick sections of high-Z materials. CST is best applied to thinner sections of lower Z materials. The following provides a general idea of the range of CST applicability when using a 160 keV constant potential X-ray source:

Material

Practical Thickness Range

Steel

Up to about 3 mm (1/8in.)

Aluminum

Up to about 25 mm (1 in.)

Aerospace composites

Up to about 50 mm (2 in.)

Polyurethane Foam

Up to about 300 mm (12 in.)

The limitations of the technique must also consider the required X, Y, and Z axis resolutions, the speed of image formation, image quality and the difference in the X-ray scattering characteristics of the parent material and the internal features that are to be imaged.

1.5The values stated in both inch-pound and SI units are to be regarded separately as the standard. The values given in parentheses are for information only.

1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM E 1316 : 2022 : REV A Standard Terminology for Nondestructive Examinations
ASTM E 1255 : 2023 Standard Practice for Radioscopy
ASTM E 1316 : 2024 : REV B Standard Terminology for Nondestructive Examinations
ASTM E 1316 : 2024 Standard Terminology for <?Pub Dtl?>Nondestructive Examinations
ASTM E 1475 : 2013 : R2018 Standard Guide for Data Fields for Computerized Transfer of Digital Radiological Examination Data
ASTM E 1475 : 2013 : R2023 Standard Guide for Data Fields for Computerized Transfer of Digital Radiological Examination Data
ASTM E 747 : 2018 Standard Practice for Design, Manufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiology
ASTM E 1647 : 2016 Standard Practice for Determining Contrast Sensitivity in Radiology
ASTM E 1316 : 2023 : REV A Standard Terminology for Nondestructive Examinations
ASTM E 747 : 2024 Standard Practice for Design, Manufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiography
ASTM E 1647 : 2016 : R2022 Standard Practice for Determining Contrast Sensitivity in Radiology
ASTM E 1316 : 2024 : REV A Standard Terminology for Nondestructive Examinations
ASTM E 1316 : 2023 Standard Terminology for Nondestructive Examinations
ASTM E 1316 : 2023 : REV B Standard Terminology for Nondestructive Examinations
ASTM E 1255 : 2016 Standard Practice for Radioscopy

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.