ASTM E 1939 : 2005
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Standard Practice for Blood Irradiation Dosimetry
Hardcopy , PDF
15-03-2002
English
15-05-2005
CONTAINED IN VOL. 12.02, 2001 Gives dosimetric and irradiator installation qualification procedures for use in the irradiation of blood and related products by blood-banks.
Committee |
E 61
|
DocumentType |
Standard
|
Pages |
13
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
1.1 This practice outlines irradiator installation qualification, operational qualification, performance qualification, and routine product processing dosimetric procedures to be followed in the irradiation of blood and blood components by the blood-banking community. If followed, these procedures will help to ensure that the products processed with ionizing radiation from gamma, X-rays (bremsstrahlung), or electron sources receive absorbed doses within a predetermined range. 1.2 This practice covers dosimetry for the irradiation of blood for these types of irradiators: self-contained irradiators (free-standing irradiators) utilizing 137Cs, 60Co or X-rays (bremsstrahlung), teletherapy units, and electron accelerators. The absorbed dose range for blood irradiation is typically 15 Gy to 50 Gy. In some jurisdictions, the absorbed dose range for blood irradiation is 25 Gy to 50 Gy. 1.3 The energy range is typically from approximately 40 keV to 5 MeV for photons, and up to 10 MeV for electrons. 1.4 This practice also covers the use of radiation-sensitive indicators for the visual and qualitative indication that the product has been irradiated. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability or regulatory limitations prior to use.
ASTM E 2116 : 2013 | PRACTICE FOR DOSIMETRY FOR A SELF-CONTAINED DRY-STORAGE GAMMA-RAY IRRADIATOR |
ASTM E 1275 : 2013 | Standard Practice for Use of a Radiochromic Film Dosimetry System |
ASTM E 1608 : 2015 | Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7.5 MeV |
ASTM E 177 : 2014 : REDLINE | Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods |
ASTM E 1539 : 2005 | Standard Guide for Use of Radiation-Sensitive Indicators |
ASTM E 1026 : 2015 : REDLINE | Standard Practice for Using the Fricke Dosimetry System |
ASTM E 1538 : 2009 | PRACTICE FOR USE OF THE ETHANOL-CHLOROBENZENE DOSIMETRY SYSTEM |
ASTM E 1607 : 2013 | Standard Practice for Use of the Alanine-EPR Dosimetry System |
ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
ASTM E 1707 : 2015 | Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing |
ASTM E 170 : 2017 : REDLINE | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 668 : 2013 : REDLINE | Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices |
ASTM E 1540 : 2004 | Standard Practice for Use of a Radiochromic Liquid Dosimetry System |
ASTM E 666 : 2014 : REDLINE | Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.