Standard Practice for Use of a Thermoluminescence-Dosimetry System (TLD System) for Radiation Processing

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-10-2021

€56.53
Excluding VAT

Committee
E 61
DocumentType
Standard Practice
Pages
8
ProductNote
References to ISO/ASTM standards were editorially updated in December 2024.
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1This practice covers procedures for the use of thermoluminescence dosimeters (TLDs) to measure the absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. Thermoluminescence-dosimetry systems (TLD systems) are generally used as routine dosimetry systems.

1.2The thermoluminescence dosimeter (TLD) is classified as a type II dosimeter on the basis of the complex effect of influence quantities on the dosimeter response. See ASTM Practice 52628.

1.3This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ASTM 52628 “Practice for Dosimetry in Radiation Processing” for a TLD system. It is intended to be read in conjunction with ASTM 52628.

1.4This practice covers the use of TLD systems under the following conditions:

1.4.1The absorbed-dose range is from 1 Gy to 10 kGy.

1.4.2The absorbed-dose rate is between 1 × 10-2 and 1 × 1010 Gy s-1.

1.4.3The radiation-energy range for photons and electrons is from 0.1 to 50 MeV.

1.5This practice does not cover measurements of absorbed dose in materials subjected to neutron irradiation.

1.6This practice does not cover procedures for the use of TLDs for determining absorbed dose in radiation-hardness testing of electronic devices or for clinical dosimetry. Procedures for the use of TLDs for radiation-hardness testing are given in ASTM Practice E668. Procedures for use of TLDs in clinical dosimetry are given in ISO 28057.

1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.8This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.