• Shopping Cart
    There are no items in your cart

ASTM E 200 : 2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Preparation, Standardization, and Storage of Standard and Reagent Solutions for Chemical Analysis

Available format(s)

Hardcopy , PDF

Superseded date

14-07-2023

Superseded by

ASTM E 200 : 2016

Language(s)

English

Published date

15-12-2008

€74.48
Excluding VAT

Committee
E 15
DocumentType
Standard Practice
Pages
16
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This practice covers procedures for the preparation, standardization, and storage of the standard volumetric solutions and reagent testing solutions commonly used in chemical analysis.

1.2 The information in this practice is arranged as follows:

Sections
Referenced Documents 2
Terminology 3
Significance and Use 4
Apparatus 5
Temperature effects 6
Measurements 7
Reagents 8
Concentration of solutions 9
Mixing of solutions10
Storage of solutions11
Preparation and standardization of solutions12
Precision and Bias13
Sodium hydroxide solution, 0.02 to 1.0 meq/mL (N) 14 to 19
Hydrochloric acid, 0.02 to 1.0 meq/mL (N)20 to 28
Sulfuric acid, 0.02 to 1.0 meq/mL (N)29 to 33
Hydrochloric acid, special 1 meq/mL (N)34 to 38
Sulfuric acid, special 1meq/mL (N)39 to 43
Silver nitrate solution, 0.1 meq/mL (N)44 to 48
Ammonium thiocyanate solution, 0.1 meq/mL (N)49 to 53
Iodine solution, 0.1 meq/mL (N)54 to 58
Sodium thiosulfate solution, 0.1 meq/mL (N)59 to 63
Potassium permanganate solution, 0.1 meq/mL (N) 64 to 68
Potassium dichromate solution, 0.1 meq/mL(N)69 to 73
Methanolic sodium hydroxide solution, 0.5 meq/mL (N) 74 to 79
Ceric sulfate solution, 0.1 meq/mL (N)80 to 84
Acetous perchloric acid, 0.1 meq/mL (N)85 to 89
Disodium ethylenediaminetetraacetate solution, 0.05 mol/L(M)90 to 94
Standard ion solutions95
Nonstandardized reagent solutions and indicator solutions96

1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific warning statements are given throughout this practice.