1.1This guide describes methods for determining and evaluating causes of water leakage of exterior walls. For this purpose, water penetration is considered leakage, and therefore problematic, if it exceeds the planned resistance or temporary retention and drainage capacity of the wall, is causing or is likely to cause premature deterioration of a building or its contents, or is adversely affecting the performance of other components. A wall is considered a system including its exterior and interior finishes, fenestration, structural components, and components for maintaining the building interior environment.
1.2Investigative techniques discussed may be intrusive, disruptive, or destructive. It is the responsibility of the investigator to establish the limitations of use, to anticipate and advise of the destructive nature of some procedures, and to plan for patching and selective reconstruction as necessary.
1.3The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.3.1Exception—Solely inch-pound units are stated in 10.3.1, 10.3.2.1, X1.5.3.7, X2.5.1.3, X3.4.3.3, X5.1.2.2, X5.5.5, X5.6.3, and X8.5.1.3.
1.4This practice does not purport to address all of the safety concerns, if any, associated with its use. Establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Awareness of safety and familiarity with safe procedures are particularly important for above-ground operations on the exterior of a building and destructive investigative procedures which typically are associated with the work described in this guide.
1.5This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
| ASTM C 1401 : 2023 | Standard Guide for Structural Sealant Glazing |
| ASTM D 7297 : 2021 | Standard Practice for Evaluating Residential Indoor Air Quality Concerns |
| ASTM E 3258 : 2025 | Standard Guide for Evaluation of Changes to the Thermal, Moisture and Ventilation Performance of Existing Roof Enclosures (with Vented or Sealed Attic or Rafter Spaces) |
| ASTM E 3069 : 2019 : REV A : R2025 | Standard Guide for Evaluation and Rehabilitation of Mass Masonry Walls for Changes to Thermal and Moisture Properties of the Wall |
| ASTM D 7338 : 2026 | Standard Guide for Assessment Of Fungal Growth in Buildings |
| ASTM E 2556/E2556M : 2010 : R2022 | Standard Specification for Vapor Permeable Flexible Sheet Water-Resistive Barriers Intended for Mechanical Attachment |
| ASTM E 2359/E2359M : 2025 | Standard Test Method for Field Pull Testing of an In-Place Wall Assembly with an Exterior Insulation and Finish System (EIFS) or EIFS with Drainage System |
| ASTM E 860 : 2007 : R2013 : EDT 2 | Standard Practice for Examining And Preparing Items That Are Or May Become Involved In Criminal or Civil Litigation |
| ASTM E 1105 : 2015 | Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference |
| ASTM C 1601 : 2022 : REV A | Standard Test Method for Field Determination of Water Penetration of Masonry Wall Surfaces |
| ASTM C 1715/C1715M : 2021 | Standard Test Method for Evaluation of Water Leakage Performance of Masonry Wall Drainage Systems |
| ASTM C 1715/C1715M : 2022 | Standard Test Method for Evaluation of Water Leakage Performance of Masonry Wall Drainage Systems |
| ASTM E 1105 : 2015 : R2023 | Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference |
| ASTM E 631 : 2015 : R2024 | Standard Terminology of Building Constructions |
| ASTM E 547 : 2000 : R2016 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference |
| ASTM C 1601 : 2020 | Standard Test Method for Field Determination of Water Penetration of Masonry Wall Surfaces |
| ASTM E 631 : 2015 | Standard Terminology of Building Constructions |
| ASTM E 1188 : 2023 | Standard Practice for Collection and Preservation of Information and Physical Items by a Technical Investigator |
| ASTM E 331 : 2000 : R2023 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference |
| ASTM C 1715/C1715M : 2015 | Standard Test Method for Evaluation of Water Leakage Performance of Masonry Wall Drainage Systems |
| ASTM C 1601 : 2022 | Standard Test Method for Field Determination of Water Penetration of Masonry Wall Surfaces |
| ASTM E 1188 : 2011 : R2017 | Standard Practice for Collection and Preservation of Information and Physical Items by a Technical Investigator |
| ASTM E 331 : 2000 : R2016 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference |
| ASTM E 547 : 2000 : R2024 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference |
| ASTM E 860 : 2022 | Standard Practice for Examining and Preparing Items That Are or May Become Involved in Criminal or Civil Litigation |