ASTM E 2217 : 2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Design and Construction of Aerospace Cleanrooms and Contamination Controlled Areas
Hardcopy , PDF
13-01-2020
English
01-04-2012
Committee |
E 21
|
DocumentType |
Standard Practice
|
Pages |
14
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 The purpose of this practice is to provide design and construction guidelines for contamination controlled facilities used in the assembly and integration of aerospace hardware. The guidelines herein are intended to ensure that the facilities, when used properly, will meet the cleanliness requirements of aerospace hardware and processes. The objective is to limit contamination due to the deposition of particulate and molecular contaminants on flight hardware surfaces.
1.2 One cleanliness classification of a facility is the airborne particle concentrations in accordance with ISO 14644-1 and 14644-2. Airborne particle concentrations in accordance with FED-STD-209E are included for reference. This simple classification is inadequate to describe a facility that will support the assembly and integration of spacecraft. The extended duration of hardware exposure during fabrication and testing, the sensitivity of the hardware to hydrocarbons and other molecular contaminants, and the changing requirements during assembly and integration must be considered in addition to the airborne particle concentrations.
1.3 The guidelines specified herein are intended to provide facilities that will effectively restrict contaminants from entering the facility, limit contamination generated by and within the facility, and continuously remove airborne contaminants generated during normal operations. Some items of support hardware, such as lifting equipment, stands, and shoe cleaners, are addressed since these items are often purchased and installed with the facility and may require accommodation in the design of the facility.
1.4 Active filtration of molecular contaminants (such as hydrocarbons, silicones, and other chemicals) is discussed. Such active filtration of molecular contaminants may be required for the processing of highly sensitive optical devices, especially infrared and cryogenic sensors. Control of microbiological contamination is not included although HEPA (High Efficiency Particulate Air) filtration will provide some control of airborne bacteria, spores, and other viable contaminants that are typically carried on particles of sizes 0.3 μm and larger. Control of radioactive contamination and accommodation of very hazardous materials such as propellants, strong acids or caustics, or carcinogens are not addressed.
1.5 No facility will compensate for excessive contamination generated inside the facility. In addition to an effective facility design, the user must also institute a routine maintenance program (see Practice E2042) for the facility, and personnel and operational disciplines that limit the transfer of contaminants through entry doors and contaminant generation inside the facility.
1.6 This practice only addresses guidelines for contamination control in facility design. It must be implemented in compliance with all mandatory government and regulatory building and safety codes. References to related cleanroom standards and U.S. building codes and standards may be found in IEST-RP-CC012.
1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7.1 The values given in parentheses are provided for information only and are not considered standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 2312 : 2011 : R2019 | Standard Practice for Tests of Cleanroom Materials |
ASTM E 1560 : 2018 | Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers |
ASTM E 1548 : 2009 : R2017 | Standard Practice for Preparation of Aerospace Contamination Control Plans |
ASTM E 2352 : 2019 | Standard Practice for Aerospace Cleanrooms and Associated Controlled Environments—Cleanroom Operations |
ASTM E 1235 : 1995 : EDT 1 | Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft |
ASTM E 2088 : 2000 | Standard Practice for Selecting, Preparing, Exposing, and Analyzing Witness Surfaces for Measuring Particle Deposition in Cleanrooms and Associated Controlled Environments |
ASTM E 1548 : 2009 : R2017 | Standard Practice for Preparation of Aerospace Contamination Control Plans |
ASTM E 1234 : 1995 : EDT 1 | Standard Practice for Handling, Transporting, and Installing Nonvolatile Residue (NVR) Sample Plates Used in Environmentally Controlled Areas for Spacecraft |
ASTM E 1235 : 2012 | Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft |
ASTM E 1216 : 1999 | Standard Practice for Sampling for Particulate Contamination by Tape Lift |
ASTM E 1548 : 2009 | Standard Practice for Preparation of Aerospace Contamination Control Plans |
ASTM E 1548 : 2003 | Standard Practice for Preparation of Aerospace Contamination Control Plans |
ASTM E 2042 : 1999 | Standard Practice for Cleaning and Maintaining Controlled Areas and Clean Rooms |
ASTM E 1548 : 1993 : R1998 | Standard Practice for Preparation of Aerospace Contamination Control Plans |
ASTM E 1234 : 2012 | Standard Practice for Handling, Transporting, and Installing Nonvolatile Residue (NVR) Sample Plates Used in Environmentally Controlled Areas for Spacecraft |
ASTM E 2088 : 2006 : R2015 | Standard Practice for Selecting, Preparing, Exposing, and Analyzing Witness Surfaces for Measuring Particle Deposition in Cleanrooms and Associated Controlled Environments |
ASTM E 1235 : 2001 | Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft |
ASTM E 2088 : 2006 : R2011 | Standard Practice for Selecting, Preparing, Exposing, and Analyzing Witness Surfaces for Measuring Particle Deposition in Cleanrooms and Associated Controlled Environments |
ASTM E 1234 : 2001 | Standard Practice for Handling, Transporting, and Installing Nonvolatile Residue (NVR) Sample Plates Used in Environmentally Controlled Areas for Spacecraft |
ASTM E 1216 : 2011 | Standard Practice for Sampling for Particulate Contamination by Tape Lift |
ASTM E 1216 : 2006 | Standard Practice for Sampling for Particulate Contamination by Tape Lift |
ASTM E 1216 : 2011 : R2016 | Standard Practice for Sampling for Particulate Contamination by Tape Lift |
ASTM E 1235 : 2008 | Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft |
ASTM E 2042 : 2004 | Standard Practice for Cleaning and Maintaining Controlled Areas and Clean Rooms |
ASTM E 1216 : 1999 : R2005 | Standard Practice for Sampling for Particulate Contamination by Tape Lift |
ASTM E 1234 : 2007 | Standard Practice for Handling, Transporting, and Installing Nonvolatile Residue (NVR) Sample Plates Used in Environmentally Controlled Areas for Spacecraft |
ASTM E 2088 : 2006 | Standard Practice for Selecting, Preparing, Exposing, and Analyzing Witness Surfaces for Measuring Particle Deposition in Cleanrooms and Associated Controlled Environments |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.