ASTM E 2257 : 2017 : REDLINE

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Room Fire Test of Wall and Ceiling Materials and Assemblies

Available format(s)

PDF

Superseded date

17-06-2022

Language(s)

English

Published date

24-04-2017

€74.48
Excluding VAT

CONTAINED IN VOL. 04.07, 2017 Defines under specified fire-exposure conditions, the contribution to room fire growth provided by wall or ceiling materials and assemblies, or both.

Committee
E 05
DocumentType
Redline
Pages
19
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This is a fire-test-response standard.

1.2This test method is intended to evaluate, under specified fire-exposure conditions, the contribution to room fire growth provided by wall or ceiling materials and assemblies, or both. The method is not intended to evaluate the fire endurance of assemblies or fires originating in the wall assembly. The method provides a means to evaluate the effectiveness of thermal barriers in restricting the contribution of combustible materials in the wall assembly to fire growth in a room fire.

1.3This test method, simulating a fire in the corner of a 2420 by 3630 mm (8 by 12 ft) room containing a single open doorway, provides a means to evaluate the relative performance of specified wall and ceiling materials or assemblies when they are used together in the same relationship within an enclosure, and simulating the manner in which they will be used.

1.4This test method is intended to evaluate the contribution to fire growth provided by a surface product using a specified ignition source. It shall, however, be noted that the type, position and heat output of the ignition source will considerably influence fire growth. The thermal exposure conditions from the ignition source specified in this method will result in flashover during the 20 min duration for many common finish materials, in particular if specimens are mounted on the walls and the ceiling (standard configuration).

1.5This test method provides a means for evaluating wall and ceiling finish materials and assemblies, including panels, tiles, boards, sprayed or brushed coatings, etc. This test method is not intended to evaluate flooring materials or furnishings.

1.6This method shall be used in conjunction with Guide E603, which covers instrumentation and the general effect of various parameters, and Guide E2067, which deals with full-scale oxygen consumption calorimetry.

1.7The values stated in SI units are to be regarded as the standard. The units given in parentheses are for information only.

1.8The text of this standard references notes and footnotes which provide explanatory information. These notes and footnotes (excluding those in figures) shall not be considered as requirements of the standard.

1.9This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire-hazard or fire-risk assessment of the materials, products, or assemblies under actual fire conditions.

1.10This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.11Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

1.12This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

BS ISO 24678-6:2016 Fire safety engineering. Requirements governing algebraic formulae Flashover related phenomena
ASTM E 1590 : 2017 : REDLINE Standard Test Method for Fire Testing of Mattresses
ASTM E 1537 : 2016 : REDLINE Standard Test Method for Fire Testing of Upholstered Furniture
NFPA 555 : 2017 METHODS FOR EVALUATING POTENTIAL FOR ROOM FLASHOVER
ASTM E 2405 : 2005 Standard Test Method for Determination of Fire and Thermal Parameters of Materials Using an Intermediate Scale Test with Vertically Oriented Specimen (Withdrawn 2011)
ASTM E 2886/E2886M : 2014 Standard Test Method for Evaluating the Ability of Exterior Vents to Resist the Entry of Embers and Direct Flame Impingement
ASTM E 2280 : 2017 : REDLINE Standard Guide for Fire Hazard Assessment of the Effect of Upholstered Seating Furniture Within Patient Rooms of Health Care Facilities
NFPA 301 : 2018 SAFETY TO LIFE FROM FIRE ON MERCHANT VESSELS
ASTM E 2707 : 2015 : REDLINE Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure
ASTM F 1870 : 2016 : REDLINE Standard Guide for Selection of Fire Test Methods for the Assessment of Upholstered Furnishings in Detention and Correctional Facilities
ASTM E 2912 : 2017 : REDLINE Standard Test Method for Fire Test of Non-Mechanical Fire Dampers Used in Vented Construction
ASTM E 603 : 2017 : REDLINE Standard Guide for Room Fire Experiments
ASHRAE HDBK REFRIGERATION : 2014 ASHRAE HANDBOOK - REFRIGERATION
NFPA 289 : 2013 STANDARD METHOD OF FIRE TEST FOR INDIVIDUAL FUEL PACKAGES
ASTM E 1591 : 2013 Standard Guide for Obtaining Data for Fire Growth Models
ISO/TR 10093:2017 Plastics Fire tests Standard ignition sources
ASTM E 2574/E2574M : 2017 : REDLINE Standard Test Method for Fire Testing of School Bus Seat Assemblies
16/30291954 DC : 0 BS ISO 24678 - FIRE SAFETY ENGINEERING - REQUIREMENTS GOVERNING ALGEBRAIC EQUATIONS - PART 6: FLASHOVER RELATED PHENOMENA
ISO 24678-6:2016 Fire safety engineering — Requirements governing algebraic formulae — Part 6: Flashover related phenomena

ASTM E 603 : 2017 : REDLINE Standard Guide for Room Fire Experiments
ISO 9705:1993 Fire tests Full-scale room test for surface products
ISO 13943:2017 Fire safety — Vocabulary
ASTM E 2067 : 2015 : REDLINE Standard Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests
ASTM E 136 : 2016-02 TEST METHOD FOR BEHAVIOUR OF MATERIALS IN A VERTICAL TUBE FURNACE AT 750 DEGREES C
NFPA 265 : 2015 METHODS OF FIRE TESTS FOR EVALUATING ROOM FIRE GROWTH CONTRIBUTION OF TEXTILE OR EXPANDED VINYL WALL COVERINGS ON FULL HEIGHT PANELS AND WALLS
NFPA 286 : 2015 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.