ASTM E 2314 : 2003 : R2014

Current

Current

The latest, up-to-date edition.

Standard Test Method for Determination of Effectiveness of Cleaning Processes for Reusable Medical Instruments Using a Microbiologic Method (Simulated Use Test) (Withdrawn 2021)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

04-12-2014

€67.30
Excluding VAT

This test method is written principally for large medical instruments or instruments with internal channels or recesses (for example, flexible endoscopes) but may be used for any resuable medical instruments.

Committee
E 35
DocumentType
Test Method
Pages
6
ProductNote
Reconfirmed 2014
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1This test method is written principally for large medical instruments or instruments with internal channels or recesses (for example, flexible endoscopes) but may be used for any resuable medical instruments.

1.2This test method describes a procedure for testing the efficacy of a cleaning process for reusable medical instruments artificially contaminated with mixtures of microorganisms and simulated soil.

1.3The test method utilizes bacterial spores as tracers for foreign materials and quantifies their removal as a means of determining the efficacy of a cleaning process.

1.4The test method is designed for use by manufacturers of medical instruments and devices. However, it may also be employed by other individuals who have a knowledge of the instruments, techniques and access to appropriate facilities.

1.5Worst-case conditions can be represented by exaggerating a specific test parameter or otherwise intentionally simulating an extreme condition such as performing the test without cleaning solutions or utilizing instruments which are not new.

1.6The test procedure is devised to determine the efficacy of a cleaning process as applied to a particular instrument or group of instruments by simulating actual use situations.

1.7The test procedure may be performed on test instruments using a complete cleaning cycle or be limited to particular phases of the cycle such as precleaning, manual cleaning, automated cleaning, or rinsing.

1.8The test procedure is normally performed on a number of external and internal sites, but it may be restricted to one particular site on the instrument.

1.9A knowledge of microbiological and aseptic techniques and familiarity with the instruments is required to conduct these procedures.

Note 1:Because contamination of the surfaces of instruments may occur as a result of rinsing with tap water, bacteria-free water should be used for all rinsing when a water rinse step is part of the cleaning directions.

Note 2:Test methods to determine the effectiveness of cleaning medical instruments has only recently been actively debated, and research efforts are in their infancy. Because published experimental results are scarce, it is premature to dictate experimental reagents, conditions or acceptance criteria.

Note 3:The total elimination of the target organisms is not the goal of cleaning. Therefore, there will almost always be a number of microorganisms surviving on the test instruments unless one of the solutions or processes disinfects or sterilizes the test instrument. The results of various clinical and laboratory tests suggest that cleaning processes alone can produce a 102 to 104 log10 reduction in bioburden. The exact reduction will depend upon the precise experimental conditions. The criteria for judging cleanliness should be determined and recorded before initiation of the test procedure.

Note 4:This test protocol employs target spores as indicators or tracers for foreign materials and monitors their removal by the cleaning process. It is certainly possible that other particulate target materials, such as microbeads (latex beads) could be used in place of microbes. These alternate approaches would be more practical in those circumstances where microbiological expertise is limited.

1.10The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.11This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E 1054 : 2021 : EDT 1 Standard Practices for Evaluation of Inactivators of Antimicrobial Agents
ASTM E 1054 : 2002 Standard Test Methods for Evaluation of Inactivators of Antimicrobial Agents
ASTM E 1054 : 2008 : R2013 Standard Test Methods for Evaluation of Inactivators of Antimicrobial Agents
ASTM E 1766 : 2015 : REDLINE Standard Test Method for Determination of Effectiveness of Sterilization Processes for Reusable Medical Devices
ASTM E 1766 : 1995 : R2007 Standard Test Method for Determination of Effectiveness of Sterilization Processes for Reusable Medical Devices
ASTM D 1193 : 1977 : R1983 : EDT 1 Standard Specification for Reagent Water
ASTM E 1766 : 1995 : R2002 Standard Test Method for Determination of Effectiveness of Sterilization Processes for Reusable Medical Devices
ASTM D 1193 : 2006 : R2011 Standard Specification for Reagent Water
ASTM E 1766 : 2015 Standard Test Method for Determination of Effectiveness of Sterilization Processes for Reusable Medical Devices (Withdrawn 2023)
ASTM E 1054 : 2021 Standard Test Practices for Evaluation of Inactivators of Antimicrobial Agents
ASTM E 1766 : 1995 Standard Test Method for Determination of Effectiveness of Sterilization Processes for Reusable Medical Devices
ASTM D 1193 : 1991 Standard Specification for Reagent Water
ASTM D 1193 : 1970 Standard Specification For Reagent Water
ASTM E 1054 : 2008 Standard Test Methods for Evaluation of Inactivators of Antimicrobial Agents
ASTM D 1193 : 2006 Standard Specification for Reagent Water
ASTM D 1193 : 1999 Standard Specification for Reagent Water
ASTM D 1193 : 2006 : R2018 Standard Specification for Reagent Water

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.