ASTM E 2317 : 2004 : R2012
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Standard Guide for Conducting Renewal Microplate-Based Life-Cycle Toxicity Tests with a Marine Meiobenthic Copepod (Withdrawn 2021)
Hardcopy , PDF
22-01-2021
English
11-01-2013
CONTAINED IN VOL. 11.06, 2015 Defines procedures for obtaining laboratory data concerning the adverse effects of a test material added to seawater, but not to food, on the marine copepod Amphiascus tenuiremis, during continuous exposures of individuals, from immediately after birth, until after the beginning of reproduction using a 200 micro liter renewal microplate-culturing technique.
Committee |
E 50
|
DocumentType |
Guide
|
Pages |
16
|
ProductNote |
Reconfirmed 2012
|
PublisherName |
American Society for Testing and Materials
|
Status |
Withdrawn
|
Supersedes |
1.1This guide describes procedures for obtaining laboratory data concerning the adverse effects of a test material added to seawater, but not to food, on the marine copepod Amphiascus tenuiremis , during continuous exposures of individuals, from immediately after birth, until after the beginning of reproduction using a 200 μL renewal microplate-culturing technique. The following data are checked and recorded during the test period: stage-specific survival, number of days it takes for development from a first stage nauplius to a reproductively mature copepod, gender ratios, number of days for a female to extrude first and subsequent broods, number of days between first (and subsequent) brood extrusion(s) and hatching of first-generation nauplii, number of hatched and surviving nauplii, number of unhatched or necrotic eggs and aborted unhatching eggsacs, and the total number of females able to produce viable offspring over the entire mating period. This microplate-based full life-cycle toxicity test has a duration of approximately 17 days for toxicants that do not delay development. These procedures probably will be useful for conducting life-cycle toxicity tests with other species of copepods, although modifications might be necessary.
1.2These procedures are applicable to most chemicals, either individually, or in formulations, commercial products, or known mixtures, that can be measured accurately at the necessary concentration in water. With appropriate modifications these procedures can be used to conduct tests on temperature, dissolved oxygen, and pH and on such materials as aqueous effluents (see also Guide E1192), sediment pore waters, and surface waters. Renewal microplate tests might not be applicable to materials that have a high oxygen demand, are highly volatile, are rapidly transformed (biologically or chemically) in aqueous solutions, or are removed from test solutions in substantial quantities by the test chambers or organisms during the test. If the concentration of dissolved oxygen falls below 50 % of saturation, or the concentration of test material in the test solution decreases by more than 20 % between renewals, it might be desirable to renew the solutions more often.
ASTM E 1023 : 1984 : R2007 | Standard Guide for Assessing the Hazard of a Material to Aquatic Organisms and Their Uses |
ASTM E 1191 : 2003 : REV A | Standard Guide for Conducting Life-Cycle Toxicity Tests with Saltwater Mysids |
ASTM E 380 : 1993 | Standard Practice for Use of the Internation System of Units (SI) (the Modernized Metric System) (Withdrawn 1997) |
ASTM E 1191 : 2003 : REV A : R2014 | Standard Guide for Conducting Life-Cycle Toxicity Tests with Saltwater Mysids |
ASTM E 1023 : 1984 : R2014 | Standard Guide for Assessing the Hazard of a Material to Aquatic Organisms and Their Uses |
ASTM E 1847 : 1996 : R2008 | Standard Practice for Statistical Analysis of Toxicity Tests Conducted Under ASTM Guidelines |
ASTM E 1023 : 1984 : R2002 | Standard Guide for Assessing the Hazard of a Material to Aquatic Organisms and Their Uses |
ASTM E 1192 : 1997 : R2008 | Standard Guide for Conducting Acute Toxicity Tests on Aqueous Ambient Samples and Effluents with Fishes, Macroinvertebrates, and Amphibians |
ASTM E 1218 : 2004 : R2012 | Standard Guide for Conducting Static Toxicity Tests with Microalgae (Withdrawn 2021) |
ASTM E 1218 : 2004 | Standard Guide for Conducting Static Toxicity Tests with Microalgae |
ASTM E 1023 : 1984 : R1996 | Standard Guide for Assessing the Hazard of a Material to Aquatic Organisms and Their Uses |
ASTM E 1847 : 1996 : R2003 | Standard Practice for Statistical Analysis of Toxicity Tests Conducted Under ASTM Guidelines |
ASTM E 1191 : 2003 | Standard Guide for Conducting Life-Cycle Toxicity Tests with Saltwater Mysids |
ASTM E 1191 : 2003 : REV A : R2008 | Standard Guide for Conducting Life-Cycle Toxicity Tests with Saltwater Mysids |
ASTM E 1192 : 1997 | Standard Guide for Conducting Acute Toxicity Tests on Aqueous Ambient Samples and Effluents with Fishes, Macroinvertebrates, and Amphibians |
ASTM E 1847 : 1996 | Standard Practice for Statistical Analysis of Toxicity Tests Conducted Under ASTM Guidelines |
ASTM E 1218 : 1997 : REV A | Standard Guide for Conducting Static 96-h Toxicity Tests with Microalgae |
ASTM E 1192 : 1997 : R2003 | Standard Guide for Conducting Acute Toxicity Tests on Aqueous Ambient Samples and Effluents with Fishes, Macroinvertebrates, and Amphibians |
ASTM E 1847 : 1996 : R2013 | Standard Practice for Statistical Analysis of Toxicity Tests Conducted Under ASTM Guidelines (Withdrawn 2022) |
ASTM E 729 : 1996 | Standard Guide for Conducting Acute Toxicity Tests on Test Materials with Fishes, Macroinvertebrates, and Amphibians |
ASTM E 1191 : 1997 | Standard Guide for Conducting Life-Cycle Toxicity Tests with Saltwater Mysids |
ASTM E 1192 : 1997 : R2014 | Standard Guide for Conducting Acute Toxicity Tests on Aqueous Ambient Samples and Effluents with Fishes, Macroinvertebrates, and Amphibians |
ASTM E 1218 : 2004 : EDT 1 | Standard Guide for Conducting Static Toxicity Tests with Microalgae |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.