Standard Practice for Determining the Resistance of Single Glazed Annealed Architectural Flat Glass to Thermal Loadings

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

01-02-2006

€67.30
Excluding VAT

Committee
E 06
DocumentType
Standard Practice
Pages
10
ProductNote
Reconfirmed 2006
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 This practice covers a procedure to determine the resistance of annealed architectural flat glass to thermally induced stresses caused by exposure to sun and shadows for a specified probability of breakage (Pb). Proper use of this procedure is intended to reduce the possibility of thermal breakage of annealed glass in buildings.

1.2 This practice applies to vertical or sloped glazing in buildings.

1.3 This practice applies to monolithic and laminated glass of rectangular shape and assumes that all glass edges are simply supported.

1.4 This practice applies only to annealed flat soda-lime silica glass with clean cut, seamed, flat ground, or ground and polished edges that are free from damage. The glass may be clear or tinted as well as coated (not including coatings that reduce emissivity of the glass).

1.5 This practice does not apply to any form of wired, patterned, etched, sandblasted, drilled, notched, or grooved glass or glass with surface and edge treatments, other than those described in section , that alter the glass strength.

1.6 This practice does not address uniform loads such as wind and snow loads, safety requirements, fire, or impact resistance.

1.7 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. For conversion of quantities in various systems of measurements to SI units refer to IEEE/ASTM SI-10.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM C 1401 : 2014 Standard Guide for Structural Sealant Glazing

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.