• ASTM E 2445/E2445M : 2014

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Standard Practice for Performance Evaluation and Long-Term Stability of Computed Radiography Systems

    Available format(s):  Hardcopy, PDF

    Superseded date:  12-08-2020

    Language(s):  English

    Published date:  13-10-2014

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    This practice describes the evaluation of Computed Radiology (CR) systems for industrial radiology.

    Scope - (Show below) - (Hide below)

    1.1This practice describes the evaluation of Computed Radiology (CR) systems for industrial radiology. It is intended to ensure that the evaluation of image quality, as far as this is influenced by the CR system, meets the needs of users of this standard, and their customers, and enables process control and long-term stability of the CR system.

    1.2This practice specifies the fundamental parameters of CR systems to be measured to determine baseline performance, and to track the long term stability of the system. These tests are for applications up to 320kV. When greater than 320kV or when a gamma source is used, these tests may still be used to characterize a system, but may need to be modified as agreed between the user and cognizant engineering organization (CEO).

    1.3The CR system performance tests specified in this practice shall be completed upon acceptance of the system from the manufacturer and at intervals specified in this practice to monitor long term stability of the system. The intent of these tests is to monitor the system performance degradation and to identify when an action needs to be taken when the system degrades by a certain level.

    1.4The use of gauges2 provided in this standard is mandatory for each test. In the event these tests or gauges are not sufficient, the user, in coordination with the CEO shall develop additional or modified tests, test objects, gauges, or image quality indicators to evaluate the CR system. Acceptance levels for these ALTERNATE tests shall be determined by agreement between the user and CEO.

    1.5The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

    1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

    General Product Information - (Show below) - (Hide below)

    Committee E 07
    Document Type Standard Practice
    Publisher American Society for Testing and Materials
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM E 2033 : 2017 Standard Practice for Radiographic Examination Using Computed Radiography (Photostimulable Luminescence Method)
    ASTM E 2446 : 2016 Standard Practice for Manufacturing Characterization of Computed Radiography Systems
    ASTM E 1316 : 2011 : REV B Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2015 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2009 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 2033 : 1999 : R2013 Standard Practice for Computed Radiology (Photostimulable Luminescence Method)
    ASTM E 1316 : 2008 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2010 : REV C Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2017 Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2013 : REV C Standard Terminology for Nondestructive Examinations
    ASTM E 1647 : 2003 Standard Practice for Determining Contrast Sensitivity in Radioscopy
    ASTM E 1316 : 2000 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2019 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2014 Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2013 : REV B Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2018 Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2011 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 2007 : 2010 Standard Guide for Computed Radiography
    ASTM E 1316 : 2007 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2015 Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2019 : REV B Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2013 : REV D Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2000 Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2019 Standard Terminology for Nondestructive Examinations
    ASTM E 2002 : 1998 Standard Practice for Determining Total Image Unsharpness in Radiology
    ASTM E 2446 : 2005 : R2010 Standard Practice for Classification of Computed Radiology Systems
    ASTM E 2033 : 1999 Standard Practice for Computed Radiology (Photostimulable Luminescence Method)
    ASTM E 1316 : 2001 Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2003 Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2018 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 1647 : 2009 Standard Practice for Determining Contrast Sensitivity in Radioscopy
    ASTM E 1316 : 2006 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2016 Standard Terminology for Nondestructive Examinations
    ASTM E 2002 : 1998 : R2003 : EDT 1 Standard Practice for Determining Total Image Unsharpness in Radiology
    ASTM E 2007 : 2000 Standard Guide for Computed Radiology (Photostimulable Luminescence (PSL) Method)
    ASTM E 2002 : 1998 : R2009 Standard Practice for Determining Total Image Unsharpness in Radiology
    ASTM E 1316 : 2002 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2014 : EDT 1 Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2010 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2013 Standard Terminology for Nondestructive Examinations
    ASTM E 2007 : 2008 Standard Guide for Computed Radiography
    ASTM E 2446 : 2005 Standard Practice for Classification of Computed Radiology Systems
    ASTM E 1316 : 2017 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2016 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 1647 : 1998 : REV A Standard Practice for Determining Contrast Sensitivity in Radioscopy
    ASTM E 1316 : 2009 Standard Terminology for Nondestructive Examinations
    ASTM E 1647 : 2016 Standard Practice for Determining Contrast Sensitivity in Radiology
    ASTM E 1316 : 2002 Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2004 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 2007 : 2010 : R2016 Standard Guide for Computed Radiography
    ASTM E 1316 : 2007 : REV C Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2010 : REV B Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2013 : REV A Standard Terminology for Nondestructive Examinations
    ASTM E 2002 : 2015 Standard Practice for Determining Total Image Unsharpness and Basic Spatial Resolution in Radiography and Radioscopy
    ASTM E 2033 : 1999 : R2006 Standard Practice for Computed Radiology (Photostimulable Luminescence Method)
    ASTM E 1316 : 2007 : REV B Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2005 Standard Terminology for Nondestructive Testing
    ASTM E 1316 : 2004 Standard Terminology for Nondestructive Examinations
    ASTM E 2446 : 2015 Standard Practice for Manufacturing Characterization of Computed Radiography Systems
    ASTM E 1316 : 2007 Standard Terminology for Nondestructive Examinations
    ASTM E 1316 : 2012 Standard Terminology for Nondestructive Examinations
    ASTM E 2007 : 2000 : R2006 Standard Guide for Computed Radiology (Photostimulable Luminescence (PSL) Method)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective