Standard Practice for Ultrasonic Testing of Flat Panel Composites and Sandwich Core Materials Used in Aerospace Applications
:
Available format(s): Hardcopy, PDF
Superseded date: 02-03-2024
Language(s): English
Published date: 22-12-2017
Publisher: American Society for Testing and Materials
1.1This practice establishes two procedures for ultrasonic testing (UT) of flat panel composites and flat sandwich core panels (parallel surfaces). Typical as-fabricated lay-ups include uniaxial, cross ply and angle ply laminates; as well as honeycomb sandwich core materials. These procedures can be used throughout the life cycle of the materials; product and process design optimization, on line process control, after manufacture inspection, and in service inspection. Contact methods such as angle-beam techniques using shear waves, or surface-beam techniques using Lamb waves, are not discussed.
1.2Ultrasonic testing is a common subsurface method for detection of laminar oriented discontinuities. Two techniques can be considered based on panel surface accessibility; pulse echo for one sided and through transmission (bubblers/squirters) for two sided. As used in this practice, both require the use of a pulsed straight-beam ultrasonic longitudinal wave followed by observing indications of either the reflected (pulse-echo) or received (through transmission) wave. The general types of anomalies detected by both techniques include foreign materials, delamination, disbond/un-bond, fiber de-bonding, inclusions, porosity, and voids.
1.3This practice provides two ultrasonic test procedures. Each has its own merits and requirements for inspection and shall be selected as agreed upon in a contractual document.
1.3.1Test Procedure A, Pulse Echo (non-contacting and contacting), is at a minimum a single transducer transmitting and receiving a longitudinal wave in the range of 0.5 to 20 MHz (see Fig. 1). This procedure requires access to only one side of the specimen. This procedure can be conducted by automated or manual means. Automated and manual test results may be imaged or recorded.
FIG. 1Test Procedure A, Pulse Echo Apparatus Set-up
1.3.2Test Procedure B, Through Transmission, is a combination of two transducers. One transmits a longitudinal wave and the other receives the longitudinal wave in the range of 0.5 MHz to 20 MHz (see Fig. 2). This procedure requires access to both sides of the specimen. This procedure is automated and the examination results are recorded.
FIG. 2Test Procedure B, Through Transmission Apparatus Set-up
1.4This practice does not specify accept-reject criteria.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, environmental practices and determine the applicability of regulatory limitations prior to use.
1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
AUD CAD CHF CNY DKK EUR GBP HKD IDR INR JPY KRW MXN NOK NZD SEK SGD USD ZAR
Unfortunately, this product is not available for purchase in your region.
Features
Get in touch with us
Loading..
A free alerting service to track changes to standards.
Once you've completed your purchase you'll get a link to My Orders on: -the Confirmation page of check out -and by email You'll be able to access your Multi User Orders to add Users.
You have selected more than three (3) participants. Please contact our Customer Service team.
You have already added this product in the cart. If you would like to add additional copies of this product please adjust the Quantity in the cart. For more than 10 copies, please contact our Customer Support team on +353 (0)1 857 6730.
You have selected more than three (3) trainings. Please contact our Customer Service team.Please contact our Customer Service team on Email: sales@saiglobal.com Phone: 131 242 (Within Australia)
You have already added a product with different Currency. Please change the currency.
This product cannot be added to your cart right now. Please contact our Customer Service team on Email: info@standards.iePhone: +353(0)1 857 6730
You have already saved 6 Quotes. Please contact our Customer Service Team.