ASTM E 262 : 2017 : REDLINE
Current
The latest, up-to-date edition.
Standard Test Method for Determining Thermal Neutron Reaction Rates and Thermal Neutron Fluence Rates by Radioactivation Techniques
English
18-09-2017
CONTAINED IN VOL. 12.02, 2017 Specifies a general procedure for determining an unknown thermal-neutron fluence rate by neutron activation techniques.
Committee |
E 10
|
DocumentType |
Redline
|
Pages |
11
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
1.1The purpose of this test method is to define a general procedure for determining an unknown thermal-neutron fluence rate by neutron activation techniques. It is not practicable to describe completely a technique applicable to the large number of experimental situations that require the measurement of a thermal-neutron fluence rate. Therefore, this method is presented so that the user may adapt to their particular situation the fundamental procedures of the following techniques.
1.1.1Radiometric counting technique using pure cobalt, pure gold, pure indium, cobalt-aluminum, alloy, gold-aluminum alloy, or indium-aluminum alloy.
1.1.2Standard comparison technique using pure gold, or gold-aluminum alloy, and
1.1.3Secondary standard comparison techniques using pure indium, indium-aluminum alloy, pure dysprosium, or dysprosium-aluminum alloy.
1.2The techniques presented are limited to measurements at room temperatures. However, special problems when making thermal-neutron fluence rate measurements in high-temperature environments are discussed in 9.2. For those circumstances where the use of cadmium as a thermal shield is undesirable because of potential spectrum perturbations or of temperatures above the melting point of cadmium, the method described in Test Method E481 can be used in some cases. Alternatively, gadolinium filters may be used instead of cadmium. For high temperature applications in which aluminum alloys are unsuitable, other alloys such as cobalt-nickel or cobalt-vanadium have been used.
1.3This test method may be used to determine the equivalent 2200 m/s fluence rate. The accurate determination of the actual thermal neutron fluence rate requires knowledge of the neutron temperature, and determination of the neutron temperature is not within the scope of the standard.
1.4The techniques presented are suitable only for neutron fields having a significant thermal neutron component, in which moderating materials are present, and for which the average scattering cross section is large compared to the average absorption cross section in the thermal neutron energy range.
1.5Table 1 indicates the useful neutron-fluence ranges for each detector material.
TABLE 1 Useful Neutron Fluence Ranges of Foil Material
Foil Material | Form | ≈ Useful Range (neutrons/cm 2) |
Indium | pure or alloyed with aluminum | 103 to 1012 |
Gold | pure or alloyed with aluminum | 107 to 1014 |
Dysprosium | pure or alloyed with aluminum | 103 to 1010 |
Cobalt | pure or alloyed with aluminum | 1014 to 1020 |
1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM E 261 : 2016 : REDLINE | Standard Practice for Determining Neutron Fluence, Fluence Rate, and Spectra by Radioactivation Techniques |
ASTM E 704 : 2013 : REDLINE | Standard Test Method for Measuring Reaction Rates by Radioactivation of Uranium-238 |
ASTM E 944 : 2013-01 | GUIDE FOR APPLICATION OF NEUTRON SPECTRUM ADJUSTMENT METHODS IN REACTOR SURVEILLANCE |
ASTM E 1005 : 2016 : REDLINE | Standard Test Method for Application and Analysis of Radiometric Monitors for Reactor Vessel Surveillance |
ASTM E 1297 : 2008 | Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Niobium |
ASTM E 1297 : 2008 : R2013 | Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Niobium |
ASTM E 2006 : 2016 : REDLINE | Standard Guide for Benchmark Testing of Light Water Reactor Calculations |
ASTM E 721 : 2016 : REDLINE | Standard Guide for Determining Neutron Energy Spectra from Neutron Sensors for Radiation-Hardness Testing of Electronics |
ASTM E 481 : 2016 : REDLINE | Standard Test Method for Measuring Neutron Fluence Rates by Radioactivation of Cobalt and Silver |
ASTM E 1854 : 2013 : REDLINE | Standard Practice for Ensuring Test Consistency in Neutron-Induced Displacement Damage of Electronic Parts |
ASTM E 720 : 2016 : REDLINE | Standard Guide for Selection and Use of Neutron Sensors for Determining Neutron Spectra Employed in Radiation-Hardness Testing of Electronics |
ASTM E 177 : 2014 : REDLINE | Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods |
ASTM E 181 : 2017 : REDLINE | Standard Test Methods for Detector Calibration and Analysis of Radionuclides |
ASTM E 170 : 2017 : REDLINE | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 261 : 2016 : REDLINE | Standard Practice for Determining Neutron Fluence, Fluence Rate, and Spectra by Radioactivation Techniques |
ASTM E 481 : 2016 : REDLINE | Standard Test Method for Measuring Neutron Fluence Rates by Radioactivation of Cobalt and Silver |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-