ASTM E 2684 : 2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Measuring Heat Flux Using Surface-Mounted One-Dimensional Flat Gages
Hardcopy , PDF
12-12-2024
English
01-09-2017
Committee |
E 21
|
DocumentType |
Test Method
|
Pages |
7
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This test method describes the measurement of the net heat flux normal to a surface using flat gages mounted onto the surface. Conduction heat flux is not the focus of this standard. Conduction applications related to insulation materials are covered by Test Method C518 and Practices C1041 and C1046. The sensors covered by this test method all use a measurement of the temperature difference between two parallel planes normal to the surface to determine the heat that is exchanged to or from the surface in keeping with Fourier’s Law. The gages operate by the same principles for heat transfer in either direction.
1.2This test method is quite broad in its field of application, size and construction. Different sensor types are described in detail in later sections as examples of the general method for measuring heat flux from the temperature gradient normal to a surface (1).2 Applications include both radiation and convection heat transfer. The gages have broad application from aerospace to biomedical engineering with measurements ranging form 0.01 to 50 kW/m 2. The gages are usually square or rectangular and vary in size from 1 mm to 10 cm or more on a side. The thicknesses range from 0.05 to 3 mm.
1.3The values stated in SI units are to be regarded as the standard. The values stated in parentheses are provided for information only.
1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.5This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM C 1046 : 1995 : R2001 | Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components |
ASTM C 1046 : 1995 : R2021 | Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components |
ASTM C 1046 : 1995 : R2013 | Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components |
ASTM C 1041 : 2010 | Standard Practice for In-Situ Measurements of Heat Flux in Industrial Thermal Insulation Using Heat Flux Transducers (Withdrawn 2019) |
ASTM C 1046 : 1995 | Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components |
ASTM C 1130 : 2007 | Standard Practice for Calibrating Thin Heat Flux Transducers |
ASTM C 1041 : 1985 : R2007 | Standard Practice for In-Situ Measurements of Heat Flux in Industrial Thermal Insulation Using Heat Flux Transducers |
ASTM C 1130 : 1990 : R2001 | Standard Practice for Calibrating Thin Heat Flux Transducers |
ASTM C 1130 : 1990 : R1995 : EDT 1 | Standard Practice for Calibrating Thin Heat Flux Transducers |
ASTM C 518 : 2002 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
ASTM C 1046 : 1995 : R2007 | Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components |
ASTM C 1130 : 2007 : R2012 | Standard Practice for Calibrating Thin Heat Flux Transducers |
ASTM C 518 : 2017 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
ASTM C 1041 : 1985 : R2001 | Standard Practice for In-Situ Measurements of Heat Flux in Industrial Thermal Insulation Using Heat Flux Transducers |
ASTM C 1130 : 2024 | Standard Practice for Calibration of Thin Heat Flux Transducers |
ASTM C 518 : 2021 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
ASTM C 1130 : 2021 | Standard Practice for Calibration of Thin Heat Flux Transducers |
ASTM C 1041 : 1985 : R1995 : EDT 1 | Standard Practice for In-Situ Measurements of Heat Flux in Industrial Thermal Insulation Using Heat Flux Transducers |
ASTM C 518 : 1998 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
ASTM C 1130 : 2017 | Standard Practice for Calibration of Thin Heat Flux Transducers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.