• Shopping Cart
    There are no items in your cart

ASTM E 2750 : 2013 : EDT 1

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Guide for Extension of Data from Penetration Firestop System Tests Conducted in Accordance with ASTM E814

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Superseded by

ASTM E 2750 : 2017

Language(s)

English

Published date

28-02-2013

€67.30
Excluding VAT

Committee
E 05
DocumentType
Guide
Pages
7
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This guide covers the extension of results obtained from fire tests performed in accordance with Test Method E814 to applications that have not been tested. Test Method E814 evaluates the duration for which test specimens will contain a fire, retain their integrity, or both during a predetermined fire test exposure. Firestops are intended for use in fire-resistive walls and floors that are evaluated in conformance with Test Method E119.

Note 1Data obtained from firestops tested in accordance with Test Methods E119 with positive pressure can also be used.

1.2This guide is based on principles involving the extension of test data using simple considerations. The acceptance of these principles and their application is based substantially on an analogous worst-case proposition.

1.3These principles are only applicable to temperature conditions represented by the standard time-temperature curve described in Test Method E814, for systems falling within the scope of Test Method E814. This test method is a fire-test-response standard.

1.4The types of building constructions which are part of this guide are as follows: floors, walls, partitions, floor/ceiling and roof/ceiling assemblies.

1.5This guide applies to:

1.5.1a single penetrating item, or

1.5.2multiple penetrating items.

1.6This guide does not apply to joints systems tested to E119, E1966 and E2307.

1.7Penetrating items can be one of the following: metallic pipe, non-metallic pipe, metallic tubing, non-metallic tubing, metallic conduit, non-metallic conduit, flexible metal conduit, cables, cable trays, bus ducts, insulated pipes, insulated tubing, insulated conduit, insulated and non-insulated ducts, and structural members.

Metallic pipe, tubing or conduit

6.7

Insulated pipe, tubing or conduit

6.8

Non-metallic pipe, tubing or conduit

6.9 and 6.10

Flexible metal conduit

6.11.1.4 and 6.11.1.5

Cables

6.11

Cable tray

6.12

Bus duct

6.13

Non-insulated duct

6.14

Insulated duct

6.14.2

Non-structural or service support member

6.15

Mixed penetrations

6.16


1.8Assemblies can be one of the following; concrete floors or walls, masonry walls, gypsum walls, wood floor/ceiling assemblies, concrete floor/ceiling assemblies, chase wall in floor/ceiling assemblies and fire-rated insulated walls.

Concrete floors or walls

6.1

Masonry walls

6.1

Gypsum board wall assemblies

6.2

Wood floor/ceiling assemblies

6.3

Floor/ceiling assembly with concrete floor

6.4

Chase wall intersecting a floor/ceiling assembly

6.5

Fire-resistance insulated walls

6.6


1.9The extension of data using numerical calculations based on empirical data or theoretical models is not covered in this guide.

1.10This guide does not cover the substitution of one proprietary material for another proprietary material, or materials for which fire-test data are not presently available.

1.11This guide is used to predict or provide a quantitative measure of the fire hazard from a specified set of fire conditions involving specific materials, products, or assemblies. This assessment does not necessarily predict the hazard of actual fires which involve conditions other than those assumed in the analysis.

1.12This guide is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions.

1.13The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.14This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E 3038 : 2022 : REV A Standard Practice for Assessing and Qualifying Candidates as Inspectors of Firestop Systems and Fire-Resistive Joint Systems
ASTM E 3157 : 2022 Standard Guide for Understanding and Using Information Related to Installation of Firestop Systems
ASTM E 3157 : 2019 Standard Guide for Understanding and Using Information Related to Installation of Firestop Systems
ASTM E 3038 : 2016 Standard Practice for Assessing and Qualifying Candidates as Inspectors of Firestop Systems and Fire-Resistive Joint Systems

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.