1.1This guide describes basic principles of photovoltaic module design, panel assembly, and system installation to reduce the risk of fire originating from the photovoltaic source circuit.
1.2This guide is not intended to cover all scenarios which could lead to fire. It is intended to provide an assembly of generally accepted practices.
1.3This guide is intended for systems which contain photovoltaic modules and panels as dc source circuits, although the recommended practices may also apply to systems utilizing ac modules.
1.4This guide does not cover fire suppression in the event of a fire involving a photovoltaic module or system.
1.5This guide does not cover fire emanating from other sources.
1.6This guide does not cover mechanical, structural, electrical, or other considerations key to photovoltaic module and system design and installation.
1.7This guide does not cover disposal of modules damaged by a fire, or other material hazards related to such modules.
1.8Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.9This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.10This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM E 3010 : 2015 : R2019 : EDT 1 | Standard Practice for Installation, Commissioning, Operation, and Maintenance Process (ICOMP) of Photovoltaic Arrays |
ASTM E 2481 : 2012 : R2018 | Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.