ASTM E 3022 : 2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Measurement of Emission Characteristics and Requirements for LED UV-A Lamps Used in Fluorescent Penetrant and Magnetic Particle Testing
Hardcopy , PDF
21-07-2023
English
01-09-2015
CONTAINED IN VOL. 03.04, 2017 Defines the procedures for testing the performance of ultraviolet A (UV-A), light emitting diode (LED) lamps used in fluorescent penetrant and fluorescent magnetic particle testing (see Guides E709 and E2297, and Practices E165/E165M, E1208, E1209, E1210, E1219, E1417/E1417M and E1444).
Committee |
E 07
|
DocumentType |
Standard Practice
|
Pages |
8
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This practice covers the procedures for testing the performance of ultraviolet A (UV-A), light emitting diode (LED) lamps used in fluorescent penetrant and fluorescent magnetic particle testing (see Guides E709 and E2297, and Practices E165/E165M, E1208, E1209, E1210, E1219, E1417/E1417M and E1444).2 This specification also includes reporting and performance requirements for UV-A LED lamps.
1.2These tests are intended to be performed only by the manufacturer to certify performance of specific lamp models (housing, filter, diodes, electronic circuit design, optical elements, cooling system, and power supply combination) and also includes limited acceptance tests for individual lamps delivered to the user. This test procedure is not intended to be utilized by the end user.
1.3This practice is only applicable for UV-A LED lamps used in the examination process. This practice is not applicable to mercury vapor, gas-discharge, arc or luminescent (fluorescent) lamps or light guides (for example, borescope light sources).
1.4The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 3024/E3024M : 2019 | Standard Practice for Magnetic Particle Testing for General Industry |
ASTM E 1219 : 2016 | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Solvent-Removable Process |
ASTM E 1444/E1444M : 2016 : EDT 1 | Standard Practice for Magnetic Particle Testing |
ASTM E 1208 : 2016 | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Lipophilic Post-Emulsification Process |
ASTM E 1417/E1417M : 2016 : REDLINE | Standard Practice for Liquid Penetrant Testing |
ASTM E 1208 : 2016 : REDLINE | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Lipophilic Post-Emulsification Process |
ASTM E 3024/E3024M : 2016 | Standard Practice for Magnetic Particle Testing for General Industry |
ASTM E 1210 : 2016 | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Hydrophilic Post-Emulsification Process |
ASTM E 165/E165M : 2018 | Standard Practice for Liquid Penetrant Testing for General Industry |
ASTM E 1417/E1417M : 2016 | Standard Practice for Liquid Penetrant Testing |
ASTM E 1209 : 2018 | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Water-Washable Process |
SAE AMS 2647F : 2017 | FLUORESCENT PENETRANT INSPECTION, AIRCRAFT AND ENGINE COMPONENT MAINTENANCE |
ASTM E 2297 : 2015 : REDLINE | Standard Guide for Use of UV-A and Visible Light Sources and Meters used in the Liquid Penetrant and Magnetic Particle Methods |
ANSI/NCSL Z540 3 : 2006(R2013) | REQUIREMENTS FOR THE CALIBRATION OF MEASURING AND TEST EQUIPMENT |
ASTM E 1219 : 2016 : REDLINE | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Solvent-Removable Process |
ANSI/ISO/IEC 17025:2005 | General Requirements For The Competence Of Testing And Calibration Laboratories |
ASTM E 1417/E1417M : 2016 : REDLINE | Standard Practice for Liquid Penetrant Testing |
ASTM E 1210 : 2016 : REDLINE | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Hydrophilic Post-Emulsification Process |
ASTM E 1444 : 2005 | Standard Practice for Magnetic Particle Testing |
ASTM E 1209 : 2010 | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Water-Washable Process |
ASTM E 2297 : 2015 : REDLINE | Standard Guide for Use of UV-A and Visible Light Sources and Meters used in the Liquid Penetrant and Magnetic Particle Methods |
ASTM E 1208 : 2016 : REDLINE | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Lipophilic Post-Emulsification Process |
ASTM E 709 : 2015 : REDLINE | Standard Guide for Magnetic Particle Testing |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.