ASTM E 3029 : 2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Determining Relative Spectral Correction Factors for Emission Signal of Fluorescence Spectrometers
Hardcopy , PDF
13-01-2023
English
14-10-2015
CONTAINED IN VOL. 03.06, 2015 Specifies three methods for determining the relative spectral correction factors for grating-based fluorescence spectrometers in the ultraviolet-visible spectral range.
Committee |
E 13
|
DocumentType |
Standard Practice
|
Pages |
5
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This practice (1)2 describes three methods for determining the relative spectral correction factors for grating-based fluorescence spectrometers in the ultraviolet-visible spectral range. These methods are intended for instruments with a 0°/90° transmitting sample geometry. Each method uses different types of transfer standards, including 1) a calibrated light source (CS), 2) a calibrated detector (CD) and a calibrated diffuse reflector (CR), and 3) certified reference materials (CRMs). The wavelength region covered by the different methods ranges from 250 to 830 nm with some methods having a broader range than others. Extending these methods to the near infrared (NIR) beyond 830 nm will be discussed briefly, where appropriate. These methods were designed for scanning fluorescence spectrometers with a single channel detector, but can also be used with a multichannel detector, such as a diode array or a CCD.
1.2The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 8044 : 2016 | Standard Test Method for Evaluation of Asphalt Mixture Cracking Resistance using the Semi-Circular Bend Test (SCB) at Intermediate Temperatures |
ASTM E 2719 : 2009 : R2014 | Standard Guide for Fluorescence—Instrument Calibration and Qualification |
ASTM E 578 : 2007 : R2021 | Standard Test Method for Linearity of Fluorescence Measuring Systems |
ASTM E 578 : 2007 : R2013 | Standard Test Method for Linearity of Fluorescence Measuring Systems |
ASTM E 2719 : 2009 | Standard Guide for Fluorescence<span class='unicode'>—</span>Instrument Calibration and Qualification |
ASTM E 2719 : 2009 : R2022 | Standard Guide for Fluorescence—Instrument Calibration and Qualification |