ASTM E 3082 : 2017

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Methods for Determining the Effectiveness of Fire Retardant Treatments for Natural Christmas Trees

Superseded date

08-08-2018

Published date

01-07-2017

Sorry this product is not available in your region.

CONTAINED IN VOL. 04.07, 2017 Gives a two-step testing process for determining the effectiveness of surface applied treatments for natural Christmas trees to improve fire test response.

Committee
E 05
DocumentType
Test Method
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This fire-test-response standard provides a two-step testing process for determining the effectiveness of surface applied treatments for natural Christmas trees to improve fire test response.

1.2The purpose of these test methods is to:

1.2.1Utilize a detached branch test (Method 1) to screen potential surface-applied fire retardant products and to determine their effectiveness in limiting the spread of flame and the continuation of flaming by comparing the burning characteristics of treated and untreated small Christmas tree branches subjected to a small open Bunsen-burner type flame ignition source, and

1.2.2Use whole natural Christmas trees (Method 2) to determine the effectiveness of surface applied fire retardants found to be effective in the detached branch test (Method 1) through comparison of heat release rate contribution of treated trees as compared to untreated trees when subjected to an open flame ignition source.

1.3The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.5Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

1.6The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

1.7This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM E 176 : 2018 : REV A Standard Terminology of Fire Standards

GPA 2140 : 2017 LIQUEFIED PETROLEUM GAS SPECIFICATIONS AND TEST METHODS
NFPA 289 : 2013 STANDARD METHOD OF FIRE TEST FOR INDIVIDUAL FUEL PACKAGES
ASTM E 2067 : 2015 : REDLINE Standard Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests
UL 1975:3ED 2006-11-27 Standard for Fire Tests for Foamed Plastics Used for Decorative Purposes
NFPA 1 : 2018 FIRE CODE

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.