ASTM E 3090/E3090M : 2020
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Methods for Strength Properties of Metal Ceiling Suspension Systems
Hardcopy , PDF
29-04-2022
English
14-04-2020
Committee |
E 33
|
DocumentType |
Test Method
|
Pages |
9
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1These test methods cover metal ceiling suspension systems used primarily to support acoustical tile, acoustical lay-in panels, or suspended T-bar type ceiling systems.
1.2These test methods cover the determination of strength properties of suspended ceiling grid system components as follows:
Tests | Subsections |
Load Carrying Capacity | 5.1 |
Connection Strength in Tension | 5.2.2; 5.2.4 |
Connection Strength in Compression | 5.2.3; 5.2.5 |
Wire Pullout Resistance | 5.3 |
1.3The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.4The following safety hazards caveat pertains only to the test methods described in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM C 635/C635M : 2017 | Standard Specification for Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings |
ASTM C 1858 : 2017 : REV A : R2021 | Standard Practice for Design, Construction, and Material Requirements for Direct Hung Suspended T-bar Type Ceiling Systems Intended to Receive Gypsum Panel Products in Areas Subject to Earthquake Ground Motions |
ASTM E 3118/E3118M : 2022 | Standard Test Methods to Evaluate Seismic Performance of Suspended Ceiling Systems by Full-Scale Dynamic Testing |
ASTM C 634 : 2013 : EDT 1 | Standard Terminology Relating to Building and Environmental Acoustics |
ASTM C 634 : 2013 : R2021 | Standard Terminology Relating to Building and Environmental Acoustics |