1.1This test method describes the thermal cycling of a Shape Memory Alloy (SMA) specimen through the phase transformation under minimal load transformation after uniaxial deformation. This method will measure residual strain after loading and unloading, recovered strain on heating, total unrecovered strain upon cooling, and transformation temperatures. This test is done to provide data for the selection of SMA materials, quality control, design allowables and actuator design.
1.2Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM E 3414 : 2023 | Standard Test Method for Constant Torque Thermal Cycling of Cylindrical Shape Memory Alloy Specimens |
ASTM F 2005 : 2021 | Standard Terminology for Nickel-Titanium Shape Memory Alloys |
ASTM F 2516 : 2022 | Standard Test Method for Tension Testing of Nickel-Titanium Superelastic Materials |
ASTM E 2368 : 2010 : R2017 | Standard Practice for Strain Controlled Thermomechanical Fatigue Testing |
ASTM E 2368 : 2024 | Standard Practice for Strain Controlled Thermomechanical Fatigue Testing |
ASTM E 4 : 2021 | Standard Practices for Force Calibration and Verification of Testing Machines |
ASTM E 4 : 2024 | Standard Practices for Force Calibration and Verification of Testing Machines |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.