ASTM E 3118/E3118M : 2022
Current
The latest, up-to-date edition.
Standard Test Methods to Evaluate Seismic Performance of Suspended Ceiling Systems by Full-Scale Dynamic Testing
Hardcopy , PDF
English
07-02-2022
Committee |
E 06
|
DocumentType |
Test Method
|
Pages |
5
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
Supersedes |
1.1These test methods help evaluate the performance of a full-scale suspended ceiling system during a seismic event using a dynamic seismic simulator (shake table).
1.2These full-scale procedures are not the only available procedures for evaluating the seismic performance of ceiling systems. These tests do not preclude the use of other small-scale or full-scale component or system testing.
1.3These test methods contain two independent procedures.
1.3.1Comparative method where the level of performance of an experimental system is compared to that of a control test system under the same set of conditions.
1.3.2Non-comparative method where a single test is conducted to establish the level of performance of an experimental system.
1.4These test procedures are valid and useful for all types of suspended ceiling systems.
1.5The text of this standard uses notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.6The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM E 3090/E3090M : 2020 | Standard Test Methods for Strength Properties of Metal Ceiling Suspension Systems |
ASTM E 580/E580M : 2024 | Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions |
ASTM C 635/C635M : 2017 | Standard Specification for Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings |
ASTM E 580/E580M : 2020 | Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions |
ASTM E 631 : 2015 : R2024 | Standard Terminology of Building Constructions |
ASTM E 3090/E3090M : 2022 | Standard Test Methods for Strength Properties of Metal Ceiling Suspension Systems |
ASTM C 635/C635M : 2022 | Standard Specification for Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings |
ASTM E 631 : 2015 | Standard Terminology of Building Constructions |
ASTM E 580/E580M : 2022 | Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions |
ASTM E 580/E580M : 2024 : REV A | Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.