• Shopping Cart
    There are no items in your cart

ASTM E 645 : 2013

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Evaluation of Microbicides Used in Cooling Water Systems

Available format(s)

Hardcopy , PDF

Superseded date

01-09-2020

Language(s)

English

Published date

01-04-2013

€67.30
Excluding VAT

CONTAINED IN VOL. 11.05, 2013 Provides a procedure for evaluating the efficacy of microbicides (algicides, bactericides, and fungicides) that will be used for controlling microbial growth in cooling water systems.

Committee
E 35
DocumentType
Standard Practice
Pages
5
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This practice outlines a procedure for evaluating the efficacy of microbicides (algicides, bactericides, and fungicides) that will be used for controlling microbial growth in cooling water systems. The microbicides will be evaluated using simulated or real cooling tower water against (1) microbes from cooling water, (2) microbes in microbiological deposits (biofilms) from operating cooling systems, or (3) microorganisms known to contaminate cooling water systems, or a combination thereof. This practice should be performed by individuals familiar with microbiological techniques.

1.2The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ISO 26986:2010 Resilient floor coverings Expanded (cushioned) poly(vinyl chloride) floor covering Specification
BS EN ISO 26986:2012 Resilient floor coverings. Expanded (cushioned) poly(vinyl chloride) floor covering. Specification Expanded (cushioned) poly(vinyl chloride) floor covering - Specification (ISO 26986:2010)
ASTM E 1054 : 2008 Standard Test Methods for Evaluation of Inactivators of Antimicrobial Agents
DIN EN ISO 26986:2012-04 Resilient floor coverings - Expanded (cushioned) poly(vinyl chloride) floor covering - Specification (ISO 26986:2010)
UNI EN ISO 26986 : 2012 RESILIENT FLOOR COVERINGS - EXPANDED (CUSHIONED) POLY(VINYL CHLORIDE) FLOOR COVERING - SPECIFICATION
ASTM D 5952 : 2008 Standard Guide for the Inspection of Water Systems for Legionella and the Investigation of Possible Outbreaks of Legionellosis (Legionnaires' Disease or Pontiac Fever)
ASTM D 5952 : 2008 : R2015 Standard Guide for the Inspection of Water Systems for Legionella and the Investigation of Possible Outbreaks of Legionellosis (Legionnaires' Disease or Pontiac Fever) (Withdrawn 2024)
I.S. EN ISO 26986:2012 RESILIENT FLOOR COVERINGS - EXPANDED (CUSHIONED) POLY(VINYL CHLORIDE) FLOOR COVERING - SPECIFICATION (ISO 26986:2010)
ASTM E 1054 : 2008 : R2013 Standard Test Methods for Evaluation of Inactivators of Antimicrobial Agents

ASTM E 1326 : 2015-07 GUIDE FOR EVALUATING NON-CULTURE MICROBIOLOGICAL TESTS
ASTM D 4412 : 2015 : REDLINE Standard Test Methods for Sulfate-Reducing Bacteria in Water and Water-Formed Deposits
ASTM E 2756 : 2010 Standard Terminology Relating to Antimicrobial and Antiviral Agents
ASTM D 4012 : 2015 : REDLINE Standard Test Method for Adenosine Triphosphate (ATP) Content of Microorganisms in Water

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.