ASTM E 671 : 1998 : R2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Specification for Maximum Permissible Thermal Residual Stress in Annealed Glass Laboratory Apparatus
Hardcopy , PDF
28-02-2022
English
30-09-2016
CONTAINED IN VOL. 14.04, 2016 Defines a limit for thermal residual stress in reusable annealed glass laboratory apparatus as determined by prescribed photoelastic measurement procedures.
Committee |
E 41
|
DocumentType |
Standard
|
Pages |
3
|
ProductNote |
Reconfirmed 2016
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This specification covers a limit for thermal residual stress in reusable annealed glass laboratory apparatus as determined by prescribed photoelastic measurement procedures.
1.2In broad classification, the laboratory glassware items covered by this specification, but not limited to, are:
beakers | Imhoff cones |
bottles, aspirator | impingers |
bottles, dropping | jars, battery |
bottles, gas washing | jars, bell |
bottles, infusion | jars, chromatography |
bottles, milk test | jars, cylindrical |
bottles, reagent | joints, ball and socket or standard taper |
bottles, weighing | manometers |
bulbs, absorption | percolators |
bulbs, leveling | pycnometers |
bulbs, sampling | stopcocks |
burets | tubes, centrifuge |
condensers | tubes, chromatography |
crystallizing dishes | tubes, color comparison (turbidity) |
culture dishes | tubes, combustion (ignition) |
custom apparatus | tubes, connecting and adapter |
cylinders, graduated | tubes, digestion |
and plain | tubes, drying |
desiccators | tubes, fermentation |
extraction tubes | tubes, thistle (spray traps) |
flasks | vapor traps |
fritted ware | viscometers |
funnels | watch glasses |
generators, Kipp | |
grinder, tissue |
1.3This specification recognizes that photoelastic measurements are proportional to the difference of the principal stresses. The limit imposed represents a safety factor to cover a situation in which one of the principal stresses may be larger than the apparent stress.
1.4This specification applies only to annealed glassware that is intended for sale as such. It excludes glassware that has been thermally tempered, ion-exchanged, or laminated with glass layers of differing expansion. The intent of this specification is to limit the residual stresses for safe consumer use in annealed glass, as it leaves the manufacturer.
1.5Stresses introduced by thermal expansion differences within the glassware are covered by this specification. Graded and glass-to-metal seals are excluded.
ASTM E 677 : 1994 : R2016 | Standard Specification for Interchangeable Spherical Ground Joints |
ASTM E1403:1997(R2019) | Standard Specification for Laboratory Glass Boiling Flasks |
ASTM E 1406 : 1995 : R2016 | Standard Specification for Laboratory Glass Filter Flasks |
ASTM E 1379 : 1990 : R2016 | Standard Specification for Laboratory Glass Dewar Flask |
ASTM E 694 : 2018 | Standard Specification for Laboratory Glass Volumetric Apparatus |
ASTM E 982 : 1994 : R2021 | Standard Specification for Laboratory Glass Test Tubes |
ASTM E 911 : 1998 : R2021 | Standard Specification for Glass Stopcocks with Polytetrafluoroethylene (PTFE) Plugs |
ASTM E 960 : 1993 : R2021 | Standard Specification for Laboratory Glass Beakers |
ASTM E 237 : 2002 : R2019 | Standard Specification for Laboratory Glass Microvolumetric Vessels (Volumetric Flasks and Centrifuge Tubes) |
ASTM E 675 : 2002 : R2019 | Standard Specification for Interchangeable Taper-Ground Stopcocks And Stoppers |
ASTM E 1377 : 1999 : R2016 | Standard Specification for Laboratory Glass Kjeldahl Flasks |
ASTM E 1378 : 1999 : R2016 | Standard Specification for Laboratory Glass Multiple Neck Distilling/Boiling Flasks |
ASTM E 1405 : 1998 : R2016 | Standard Specification for Laboratory Glass Distillation Flasks |
ASTM E 890 : 1994 : R2021 | Standard Specification for Disposable Glass Culture Tubes |
ASTM E 1094 : 2004 : R2021 | Standard Specification for Pharmaceutical Glass Graduates |
ASTM E 1293 : 2002 : R2019 | Standard Specification for Glass Measuring Pipets |
ASTM E 1096 : 1986 : R2018 | Standard Specification for Laboratory Glass Separatory Funnels |
ASTM E 676 : 2002 : R2019 | Standard Specification for Interchangeable Taper-Ground Joints |
ASTM E 1044 : 1996 : R2018 | Standard Specification for Glass Serological Pipets (General Purpose and Kahn) |
ASTM E 1404 : 1994 : R2019 | Standard Specification for Laboratory Glass Conical Flasks |
ASTM E 1273 : 1988 : R2019 | Standard Specification for Color Coding of Reusable Laboratory Pipets |
ASTM E 1273 : 1988 : R2003 | Standard Specification for Color Coding of Reusable Laboratory Pipets |
ASTM E 1157 : 1987 : R2006 | Standard Specification for Sampling and Testing of Reusable Laboratory Glassware |
ASTM F 218 : 2013 : REDLINE | Standard Test Method for Measuring Optical Retardation and Analyzing Stress in Glass |
ASTM E 1157 : 1987 : R2018 : EDT 1 | Standard Specification for Sampling and Testing of Reusable Laboratory Glassware |
ASTM E 1273 : 1988 : R2008 | Standard Specification for Color Coding of Reusable Laboratory Pipets |
ASTM E 1157 : 1987 : R1996 | Standard Specification for Sampling and Testing of Reusable Laboratory Glassware |
ASTM E 1273 : 1988 : R1997 : EDT 1 | Standard Specification for Color Coding of Reusable Laboratory Pipets |
ASTM E 1157 : 1987 : R2011 | Standard Specification for Sampling and Testing of Reusable Laboratory Glassware |
ASTM E 1273 : 1988 : R2013 | Standard Specification for Color Coding of Reusable Laboratory Pipets |
ASTM E 1157 : 1987 : R2001 : EDT 1 | Standard Specification for Sampling and Testing of Reusable Laboratory Glassware |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.