ASTM E 816 : 2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers
Hardcopy , PDF
25-03-2023
English
25-02-2015
Committee |
G 03
|
DocumentType |
Test Method
|
Pages |
11
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This test method has been harmonized with, and is technically equivalent to, ISO 9059.
1.2Two types of calibrations are covered by this test method. One is the calibration of a secondary reference pyrheliometer using an absolute cavity pyrheliometer as the primary standard pyrheliometer, and the other is the transfer of calibration from a secondary reference to one or more field pyrheliometers. This test method prescribes the calibration procedures and the calibration hierarchy, or traceability, for transfer of the calibrations.
Note 1:It is not uncommon, and is indeed desirable, for both the reference and field pyrheliometers to be of the same manufacturer and model designation.
1.3This test method is relevant primarily for the calibration of reference pyrheliometers with field angles of 5 to 6°, using as the primary reference instrument a self-calibrating absolute cavity pyrheliometer having field angles of about 5°. Pyrheliometers with field angles greater than 6.5° shall not be designated as reference pyrheliometers.
1.4When this test method is used to transfer calibration to field pyrheliometers having field angles both less than 5° or greater than 6.5°, it will be necessary to employ the procedure defined by Angstrom and Rodhe.2
1.5This test method requires that the spectral response of the absolute cavity chosen as the primary standard pyrheliometer be nonselective over the range from 0.3 to 10 μm wavelength. Both reference and field pyrheliometers covered by this test method shall be nonselective over a range from 0.3 to 4 μm wavelength.
1.6The primary and secondary reference pyrheliometers shall not be field instruments and their exposure to sunlight shall be limited to calibration or intercomparisons. These reference instruments shall be stored in an isolated cabinet or room equipped with standard laboratory temperature and humidity control.
Note 2:At a laboratory where calibrations are performed regularly, it is advisable to maintain a group of two or three secondary reference pyrheliometers that are included in every calibration. These serve as controls to detect any instability or irregularity in the standard reference pyrheliometer.
1.7This test method is applicable to calibration procedures using natural sunshine only.
ASTM E 824 : 2010 : R2018 : EDT 1 | Standard Test Method for Transfer of Calibration From Reference to Field Radiometers |
ASTM E 1125 : 2016 : R2020 | Standard Test Method for Calibration of Primary Non-Concentrator Terrestrial Photovoltaic Reference Cells Using a Tabular Spectrum |
ASTM E 1362 : 2015 : R2019 | Standard Test Methods for Calibration of Non-Concentrator Photovoltaic Non-Primary Reference Cells |
ASTM E 2527 : 2015 : R2019 | Standard Test Method for Electrical Performance of Concentrator Terrestrial Photovoltaic Modules and Systems Under Natural Sunlight |
ASTM G 90 : 2017 | Standard Practice for Performing Accelerated Outdoor Weathering of Materials Using Concentrated Natural Sunlight |
ASTM G 207 : 2011 : R2019 : EDT 1 | Standard Test Method for Indoor Transfer of Calibration from Reference to Field Pyranometers |
ASTM G 167 : 2015 | Standard Test Method for Calibration of a Pyranometer Using a Pyrheliometer |
ASTM G 167 : 2015 : R2023 | Standard Test Method for Calibration of a Pyranometer Using a Pyrheliometer |
ASTM E 772 : 2015 : R2021 | Standard Terminology of Solar Energy Conversion |
ASTM E 772 : 2015 | Standard Terminology of Solar Energy Conversion |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.