ASTM F 1160 : 2014 : R2017 : EDT 1
Current
The latest, up-to-date edition.
Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate/Metallic Coatings
Hardcopy , PDF
English
01-12-2017
CONTAINED IN VOL. 13.01, 2018 Describes the procedure for determining the shear and bending fatigue performance of calcium phosphate coatings and of porous and nonporous metallic coatings and for determining the bending fatigue performance of metallic coatings oversprayed with calcium phosphate.
Committee |
F 04
|
DocumentType |
Test Method
|
Pages |
9
|
ProductNote |
Reconfirmed EDT 1
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
Supersedes |
1.1This test method covers the procedure for determining the shear and bending fatigue performance of calcium phosphate coatings and of porous and nonporous metallic coatings and for determining the bending fatigue performance of metallic coatings over sprayed with calcium phosphate. This test method has been established based on plasma-sprayed titanium and plasma-sprayed hydroxylapatite coatings. The efficacy of this test method for other coatings has not been established. In the shear fatigue mode, this test method evaluates the adhesive and cohesive properties of the coating on a metallic substrate. In the bending fatigue mode, this test method evaluates both the adhesion of the coating as well as the effects that the coating may have on the substrate material. These methods are limited to testing in air at ambient temperature. These test methods are not intended for application in fatigue tests of components or devices; however, the test method which most closely replicates the actual loading configuration is preferred.
1.2The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM F 2083 : 2012 | Standard Specification for Knee Replacement Prosthesis |
ASTM F 2887 : 2017 | Standard Specification for Total Elbow Prostheses |
ASTM F 1609 : 2008 : R2014 | Standard Specification for Calcium Phosphate Coatings for Implantable Materials |
ASTM F 2091 : 2015 | Standard Specification for Acetabular Prostheses (Withdrawn 2023) |
ASTM F 2665 : 2009 : R2014 | Standard Specification for Total Ankle Replacement Prosthesis |
ASTM F 1672 : 2014 | Standard Specification for Resurfacing Patellar Prosthesis |
ASTM E 1012 : 2014 | Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application |
ASTM E 468 : 1990 : R2004 | Standard Practice for Presentation of Constant Amplitude Fatigue Test Results for Metallic Materials |
ASTM E 1832 : 2008 : R2012 | Standard Practice for Describing and Specifying a Direct Current Plasma Atomic Emission Spectrometer |
ASTM E 466 : 2015 : REDLINE | Standard Practice for Conducting Force Controlled Constant Amplitude Axial Fatigue Tests of Metallic Materials |
ASTM E 6 : 2002 | Standard Terminology Relating to Methods of Mechanical Testing |
ASTM E 1832 : 2008 : R2017 | Standard Practice for Describing and Specifying a Direct Current Plasma Atomic Emission Spectrometer |
ASTM E 466 : 1996 | Standard Practice for Conducting Force Controlled Constant Amplitude Axial Fatigue Tests of Metallic Materials |
ASTM E 1012 : 1999 | Standard Practice for Verification of Specimen Alignment Under Tensile Loading |
ASTM E 1012 : 2012 | Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application |
ASTM E 1012 : 2014 : EDT 1 | Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application |
ASTM E 1832 : 2008 : R2024 | Standard Practice for Describing and Specifying a Direct Current Plasma Atomic Emission Spectrometer |
ASTM E 1832 : 2003 | Standard Practice for Describing and Specifying a Direct Current Plasma Atomic Emission Spectrometer (Withdrawn 2004) |
ASTM E 1012 : 2012 : EDT 1 | Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application |
ASTM E 466 : 2021 | Standard Practice for Conducting Force Controlled Constant Amplitude Axial Fatigue Tests of Metallic Materials |
ASTM E 466 : 2015 | Standard Practice for Conducting Force Controlled Constant Amplitude Axial Fatigue Tests of Metallic Materials |
ASTM E 6 : 2015 : EDT 3 | Standard Terminology Relating to Methods of Mechanical Testing |
ASTM E 1832 : 1996 : EDT 2 | Standard Practice for Describing and Specifying a Direct-Current-Plasma Optical Emission Spectrometer |
ASTM E 6 : 2023 : REV A | Standard Terminology Relating to Methods of Mechanical Testing |
ASTM E 1012 : 2005 | Standard Practice for Verification of Test Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application |
ASTM E 467 : 2008 : R2014 | Standard Practice for Verification of Constant Amplitude Dynamic Forces in an Axial Fatigue Testing System |
ASTM E 6 : 2015 : EDT 4 : REDLINE | Standard Terminology Relating to Methods of Mechanical Testing |
ASTM E 468 : 2018 | Standard Practice for Presentation of Constant Amplitude Fatigue Test Results for Metallic Materials |
ASTM E 1832 : 2008 | Standard Practice for Describing and Specifying a Direct Current Plasma Atomic Emission Spectrometer |
ASTM E 6 : 2015 : EDT 4 | Standard Terminology Relating to Methods of Mechanical Testing |
ASTM E 6 : 2023 | Standard Terminology Relating to Methods of Mechanical Testing |
ASTM E 467 : 2021 | Standard Practice for Verification of Constant Amplitude Dynamic Forces in an Axial Fatigue Testing System |
ASTM E 1012 : 2019 | Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.