1 | Control Movement Expectations |
2 | Foot-Operated Switches Design Requirements |
3 | Pedal Location and Design Requirements |
4 | Lateral Spacing for Pedals |
5 | Design Criteria for Discrete Rotary Controls |
6 | Separation Requirements for Discrete Rotary Controls |
7 | Dimension, Resistance, and Separation of Continuous Rotary Controls |
8 | Proper Mounting of Rapidly Operated Cranks |
9 | Dimensions, Resistance, and Separations Required for Cranks |
10 | Design Criteria for Pushbuttons |
11 | Two Types of Legend Switches (Backlit Pushbuttons) |
12 | Size, Displacement, and Resistance for Legend Switches |
13 | Design Requirements for Various Types of Toggle Switches |
14 | Design Requirements for Rocker Switches |
15 | Dimensions, Resistance, and Separation for Discrete Slide Switch Controls |
16 | Dimensions, Resistance, and Separation for Continuous Slide Controls |
17 | Dimensions, Resistance, and Separation for Levers |
18 | Dimensions, Resistance, and Separation for Slide Levers |
19 | Dimensions, Displacement, and Separation of Push-Pull Controls |
20 | Visual Lines of Sight |
21 | Primary and Secondary Fields-of-view |
22 | Design Criteria for Major, Intermediate, and Minor Scale Markings |
23 | Scale Graduation, Pointer Position, and Scale Numbering Alternatives |
24 | Scale Number Placement |
25 | Color and Shape Coding of Ranges on an Analog Display |
26 | Zero Position and Pointer Movement for Circular Dial Displays |
27 | Aligned Pointers for Rapid Check Readings |
28 | Digital Display Design Requirements |
29 | Grouping Controls and Displays by Common Function |
30 | Grouping Controls and Displays by Individual Equipment |
31 | Mirror-Imaged Arrangement of Individual Equipment Control and Display Groupings (Not Recommended) |
32 | Grouping Controls and Displays by Common Equipment |
33 | Grouping Controls and Displays by Sequence of Use |
34 | Grouping with Physical Separation |
35 | Grouping with Boundary Lines and Borders |
36 | Grouping with Colored and Shaded Pads |
37 | Grouping with Sub-panels |
38 | Position of Individual Controls and Associated Displays for Right-handed Operator |
39 | Arrangement of Multiple Rows of Controls and Displays |
40 | Arrangement of Multiple Rows of Displays and a Single Row of Controls |
41 | Positional Relationship between Alarm, Display, and Control |
42 | Positional Relationship between Control Pointer and Status Indicator |
43 | Control and Display Movement Relationship |
44 | Spatial Relationship Between Controls, Displays, and Equipment |
45 | Spatial Relationships Between Equipment and Control Panels |
46 | Spatial Relationships for Redundant Controls and Displays |
47 | Panel Layout That Replicates Location of Equipment in Remote Space |
48 | Mimic of Physical Equipment Functional Layout |
49 | Mimic of Functional Groups Irrespective of Equipment Layout |
50 | Standing Body Dimensions |
51 | Seated Body Dimensions |
52 | Depth and Breadth Dimensions |
53 | Hand and Foot Dimensions |
54 | Gloved Hand Dimensions |
55 | Head Dimensions |
56 | Changes in Levels up to a Maximum of 6 mm (1/4in.) |
57 | Seated Workspace Dimensions |
58 | Dimensions for a Computer Workstation |
59 | Dimensions for Single or Multiple Personnel at a Table or Other Duty Station Not Requiring a Desk |
60 | Seating at CRT-Type Workstations |
61 | Clearance Behind a Seated Workstation |
62 | Control Mounting Height for Seated Personnel |
63 | Display Mounting Height for Seated Personnel |
64 | Control Mounting Height for Standing Personnel |
65 | Display Mounting Height for Standing Personnel |
66 | Control Mounting Height for a Kneeling Person |
67 | Display Mounting Height for Kneeling Personnel |
68 | Required Dimensions for a Kneeling Worker |
69 | Control Mounting Height for Squatting Personnel |
70 | Display Mounting Heights for Squatting Personnel |
71 | Required Dimensions for a Squatting Worker |
72 | Workplace Dimensions for Shelves with Full Access |
73 | Workplace Dimensions for Shelves Located Above a Cabinet |
74 | Workplace Dimensions for Shelves Requiring Vision Over the Top |
75 | Front Clearance Requirement for Lower Shelves |
76 | Mounting Height of Status Boards |
77 | Clearance in Front of Filing Cabinets |
78 | Workbench Dimensions |
79 | Safe Reach Distances Over an Obstacle or Barrier |
80 | Mounting Heights for Bulkhead-mounted Equipment in Passageways |
81 | Mounting Heights for Common Electrical Fixtures |
82 | Direct Spatial Relationships Between Controls and Equipment |
83 | Spatial Relationship of Fore and Aft Equipment to Controls and Displays on a Console Located Athwartship |
84 | Seated Single-operator Console Dimensions |
85 | Wraparound Seated Console |
86 | Special Width Console |
87 | Multi-tiered Standing Console |
88 | Multi-tiered Seated Console |
89 | Dimensions for Desktop Standing Console |
90 | Cargo and Ballast Transfer Consoles |
91 | Stair Dimensions |
92 | Straight Run Ramp Dimensions |
93 | Ramp with Turning Platform |
94 | Ramp with Switchback Turning Platform |
95 | Vertical Ladder Dimensions |
96 | Dimensions for a Vertical Ladder Arrangement |
97 | Platform/Landing Dimensions for Vertical Ladder Penetration |
98 | Caged Ladder Dimensions |
99 | Cage Shape and Size |
100 | Ladder and Climber Safety Device Dimensions |
101 | Extended Railing for Ladder Fall Protection (Front View) |
102 | Extended Railing for Ladder Fall Protection (Side View) |
103 | Extended Railing and Cage for Ladder Fall Protection (Front View) |
104 | Extended Railing and Cage for Ladder Fall Protection (Side View) |
105 | Handles or Hand Grabs for Use as Ladder Extensions |
106 | Handle for Transition from a Ladder to an Intermediate Platform |
107 | Recommended Design Criteria for Individual Rung Ladders |
108 | Dimensions for D-Ring Ladders |
109 | Fixed Handrail Design |
110 | Removable Handrail Dimensions |
111 | Special Handrail Design Dimensions |
112 | Transition Handrail Dimensions |
113 | Additional Personnel Movement-related Design Features |
114 | Dimensions for Rectangular Access Openings Installed in a Vertical Orientation Requiring a Step to Reach the Opening |
115 | Dimensions for Rectangular, Square, and Round Hatches, Manways, and Lightening Holes |
116 | Dimensions for Lightening Holes |
117 | Access to Vertical Escape Hatches |
118 | Access to Overhead Hatch |
119 | Access into a Cargo Hold Through a Raised Hatch |
120 | Door Placement |
121 | Desirable Upper Limits for Handwheel Torque |
122 | Mounting Heights for Handwheel Valves With Vertical Stems |
123 | Mounting Heights for Handwheel Valves With Horizontal Stems |
124 | Mounting Heights for Handwheel Valves With Angled Stems |
125 | Mounting Heights for Lever-Operated Valves With Vertical Stems |
126 | Mounting Heights for Lever-Operated Valves With Horizontal Stems |
127 | Direction of Travel for Valve Levers Accessible From One Side Only |
128 | Physical Reach from a Stooping or Squatting Position |
129 | Mounting Position for Valve Levers and Handwheels Below Standing Surface |
130 | Orientation and Reach from Ladder Parallel to Valves |
131 | Orientation and Reach from Ladder Perpendicular to Valves |
132 | Operating Valves from a Ladder |
133 | Valve Manifold for Tanks Located Athwartship |
134 | Valve Manifold for Tanks Located Fore and Aft |
135 | Valve Manifold for Fill, High-suction, and Low-suction Valves |
136 | Default Push Button |
137 | Push Button States |
138 | Radio Buttons |
139 | Check Boxes |
140 | Slider Control |
141 | Message Window Design |
142 | Finger-Operated Displacement Joystick Specifications |
143 | Trackball Dimensions, Resistance, and Clearance |
144 | Permissible Noise Exposure Limits |
145 | Large Enclosure Ventilation Requirements |
146 | Surface Reflectance Values |
147 | Health Guidance Zones for Limited Exposures |
148 | Independent Symbols |
149 | Guidelines for Labels on Consoles and Panels |
150 | Control and Control Setting Labels |
151 | Control and Display Group Labels |
152 | Control Setting Labels for Multiple Controls |
153 | Equipment Label Format |
154 | Sensor Label |
155 | Pipe Marker Labels |
156 | Pipe Marker Labels with Two Colors |
157 | Hazard Signal Word Headers |
158 | Examples of Text and Symbol on Signs |
159 | Example of Information Sign |
160 | Handle Dimensions |
161 | Use of Hand Trucks |
162 | Use of Dollies |
163 | Case Orientation |
164 | Access Opening Covers |
165 | Example of Alignment Pins |
166 | Cable Arrangements |
167 | Suggested Cable Arrangement in a Junction Box |
168 | Fluid Line Connection Recommendations |
169 | Areas To Place Items on Bulkhead |
170 | Safety Barriers |
X1.1 | Primary and Secondary Fields of View |